7. OBJECT LIBRARY
(1) Usage
This object can read the availability of each Sub Index. The following table shows the returned values of
each item.
Select the items to be saved in EEP-ROM using this object. At this time, set "00h" or "01h" for Number of
entries.
To save servo amplifier parameters in EEP-ROM, configure required settings following the table below.
When bit 1 (EEP-ROM write completed) of the control output (2D11h) is "1", saving data in EEP-ROM
has been completed.
Writing a value other than "65766173h" and "00000000h" to each item results in an error.

7.2.2 Restore default EEP-ROM parameters (1011h)

The parameter of the servo amplifier can be rewritten with the factory setting.
When "64616F6Ch" (= reverse order of ASCII code of "load") is written to Restore all default parameters
(1011h: 1) and the power in cycled, the parameter is initialized.
Sub
Item
Index
Number of entries (Number of
0
entries)
Saving all parameters (Save
1
all parameters)
2
3
For manufacturer setting
4
5
Sub
Item
Index
Number of entries (Number of
0
entries)
Saving all parameters (Save
1
all parameters)
2
3
For manufacturer setting
4
5
Sub
Index
Index
0
1
Restoring default EEP-ROM
1011h
parameters (Restore default
2
parameters)
3
4
5
7 - 18
Saved parameter
Index: 2001h to 27FFh
Setting value
01h
00000000h
65766173h ("save")
Other than above
Name
Number of entries (Number of
entries)
Restoring all default parameters
(Restore all default parameters)
For manufacturer setting
Returned value
01h
00000001h (available)
Write to EEP-ROM
Parameter
Disabled
Enabled
Error
Data
Read/
type
write
1 bytes Reading
Read/
4 bytes
write

Advertisement

Table of Contents
loading