6. MANUFACTURER FUNCTIONS

6.4 Servo amplifier life diagnosis function

You can check the cumulative energization time and the number of on/off times of the inrush relay based on
the data in the servo amplifier. This function gives an indication of the replacement time for parts of the servo
amplifier including a capacitor and a relay before they malfunction. The information of the servo amplifier life
diagnosis function can be obtained with the following objects.
Sub-
Index
Read/write
address
2C18h
0
Reading
2C19h
0
Reading
Name
Power ON cumulative time
Inrush relay ON/OFF number
6 - 5
Data
Initial
type
value
The cumulative energization time of the
4 bytes
servo amplifier is returned.
The number of on/off times of the inrush
4 bytes
relay of the servo amplifier is returned.