Ram Error P0604; Rom Error P0605; A/D Converter P0607; Stop Lights Relay Error P0610 - APRILIA RSV4 R Service Station Manual

895777
Hide thumbs Also See for RSV4 R:
Table of Contents

Advertisement

Electrical system
circuit not operational
Error cause
Replace injection ECU. The instrument panel does not indicate the presence of this error
even in the ATT status

RAM Error P0604

circuit not operational
Error cause
Replace injection ECU. The instrument panel does not indicate the presence of this error
even in the ATT status

ROM Error P0605

circuit not operational
Error cause
Replace injection ECU. The instrument panel does not indicate the presence of this error
even in the ATT status

A/D converter P0607

circuit not operational
Error cause
Replace injection ECU

Stop lights relay error P0610

short circuit to positive/ short circuit to negative / open circuit
Error cause
If shorted to positive: excessive voltage has been detected at PIN 31. If shorted to negative:
no voltage has been detected. If the circuit is open: an interruption has been detected
Troubleshooting
If shorted to positive: check the relay electrical specifications are correct by disconnecting
it from the cable harness. If they are not correct, replace the relay; if OK, restore the cable
harness (blue/pink cable)
If shorted to negative: check the relay electrical specifications are correct by disconnecting
it from the cable harness. If they are not correct, replace the relay; if OK, restore the cable
harness (blue/pink cable)
If the circuit is open: check the relay electrical characteristics are correct by disconnecting
it from the cable harness; if not OK, replace the relay, if OK, check relay connector, engine-
vehicle cable harness connector and ENGINE connector of the Marelli control unit: if not
OK, restore; if OK, check continuity of cable harness (blue/pink cable)