Page 1
GO XSE Installation Manual ENGLISH www.simrad-yachting.com...
Page 3
The warranty card is supplied as a separate document. In case of any queries, refer to the brand website of your unit or system: www.simrad-yachting.com. Compliance statements This equipment complies with: • CE under 2014/53/EU Directive Preface | GO XSE Installation Manual...
The relevant Declaration of conformity is available in the product's section at the following website: www.simrad-yachting.com. Industry Canada IC RSS-GEN, Sec 8.4 Warning Statement This device complies with Industry Canada license-exempt RSS standard(s).
Page 5
DE - Germany GR - Greece HU - Hungary IS - Iceland IE - Ireland IT - Italy LV - Latvia LI - Liechtenstein LT - Lithuania LU - Luxembourg MT - Malta NL - Netherlands Preface | GO XSE Installation Manual...
Page 6
Bluetooth SIG, Inc. Navico product references This manual refers to the following Navico products: • Broadband Sounder™ (Broadband Sounder) • Broadband 3G™ (Broadband 3G Radar) • Broadband 4G™ (Broadband 4G Radar) • DownScan Imaging™ (DownScan) Preface | GO XSE Installation Manual...
Halo™ Pulse Compression Radar (Halo Radar) • INSIGHT GENESIS® (Insight Genesis) About this manual This manual is a reference guide for installing GO XSE units. Important text that requires special attention from the reader is emphasized as follows: Ú Note: Used to draw the reader’s attention to a comment or...
CZone connection to NMEA 2000 Transducer connection Radar connector 33 Software Setup First time startup Time and Date Data source selection Device list SimNet Groups Diagnostics Damping Calibration External Alarm Setup Echosounder setup StructureScan Contents | GO XSE Installation Manual...
Page 10
62 Accessories 64 Supported data NMEA 2000 compliant PGN List 67 Technical specifications All units 69 Dimensional drawings 5" unit dimensional drawings 7" unit dimensional drawings 9" unit dimensional drawings 12" unit dimensional drawings Contents | GO XSE Installation Manual...
Mounting screws (4x #4 x 3/4" PN HD SS) Sun cover Cable Combined power and NMEA 2000 cable - 5" unit Power cable - 7", 9" and 12" units Fuseholder and fuse (3 A, ATC-blade) Check the contents | GO XSE Installation Manual...
Page 12
Mounting screws (4x #10 x 3/4" PN HD SS) • Bracket knobs (2x) C: Bracket mounting kit - 12" unit • U bracket (metal) • Mounting screws (4x #10 x 3/4" PN HD SS) • Bracket knobs (2x) Check the contents | GO XSE Installation Manual...
The unit is intended for 12 V DC operation and will accept the moderate fluctuations commonly seen in DC systems. Front controls Touch screen Power button Press and hold to turn the unit ON/OFF. Press once to display the System Controls dialog. Overview | GO XSE Installation Manual...
NMEA2000 POWER SONAR Radar - radar (Ethernet) connection NMEA 2000 - data input / output Power - 12 V DC supply input Sonar - CHIRP, Broadband, DownScan, and SideScan imaging (dependent on the transducer) Overview | GO XSE Installation Manual...
The card reader door should always be securely shut immediately after inserting or removing a card, in order to prevent possible water ingress. Card reader on the 5" unit Card reader on the 7" and 9" units Card reader on the 12" unit Overview | GO XSE Installation Manual...
If in doubt, consult a qualified boat builder, or marine electronics installer. Ú Note: Where flush mounted, the enclosure should be dry and well ventilated. In small enclosures, it may be required to fit forced cooling. Installation | GO XSE Installation Manual...
Use only 304 or 316 stainless steel fasteners. Screw down the bracket. Snap the unit to the bracket. Installation | GO XSE Installation Manual...
Page 18
Tilt the unit to the desired position angle. Removing the unit from the quick release bracket Pull and hold the release handle and then pull the unit from the bracket. Installation | GO XSE Installation Manual...
Page 19
Mount the unit to the bracket using the knobs. Hand tighten only. The ratchet teeth in the bracket and unit ensure a positive grip and prevent the unit from changing from the desired angle. Installation | GO XSE Installation Manual...
When the first locking tab is released and an opening is visible, carefully release the remaining locking tabs and remove the bezel. Installation | GO XSE Installation Manual...
Secure the bezel to the screen frame by gently pressing the bezel against the screen frame. Transducer installation For transducer installation information, refer to separate installation instructions included with the transducer. Installation | GO XSE Installation Manual...
24 V DC systems. Warning: The positive supply wire (red) should always be connected to (+) DC with the supplied fuse or a circuit breaker (closest available to fuse rating). Wiring | GO XSE Installation Manual...
NMEA 2000 cable and connector Connect Red to (+) DC using a 3 amp fuse. Connect Black to (-) DC. The unit can be powered on and off using the power button on the front of the case. Wiring | GO XSE Installation Manual...
The units can be powered on and off using the power button on the front of the case. Power Control connection The yellow Power Control wire in the power cable is an input that will turn on the unit when power is applied. Wiring | GO XSE Installation Manual...
Page 25
Ú Note: The unit cannot be powered down by power button, but can be put in to standby mode. (The screen backlight turns off.) Wiring | GO XSE Installation Manual...
Page 26
Ú Note: Engine start batteries and house batteries should have a common ground connection. Power cable connector to unit Positive wire (red) Ground wire (black) Power control wire (yellow) Alarm wire (blue) Ignition switch Wiring | GO XSE Installation Manual...
Negative power wire (black) Positive power wire (red) Power control wire (yellow) Alarm wire (blue) Connecting control devices The unit can be controlled with an OP40 or OP50 Remote controller connected on the NMEA 2000 network. Wiring | GO XSE Installation Manual...
While most Navico products use Micro-C cabling and connectors, some products still use proprietary SimNet connectors, which are easily made compatible with adaptor cables. • A network consists of a linear backbone from which drop-cables connect to NMEA 2000 compliant devices. Wiring | GO XSE Installation Manual...
Page 29
If joining to an existing NMEA 2000 network that already has its own power supply, do not make another power connection elsewhere in the network, and ensure the existing network is not powered by 24 V DC. Wiring | GO XSE Installation Manual...
Network interface bridge to join the two network backbones together. The CZone / NMEA 2000 Network interface bridge isolates the power of the two networks, but allows data to be freely shared between both sides. Wiring | GO XSE Installation Manual...
Radar connector Ú Note: The 5" unit does not have a Radar port. The Radar port allows connecting the unit to your radar scanner using a 5 pin Ethernet connector. Wiring | GO XSE Installation Manual...
Page 32
Unit socket (female) Cable plug (male) Purpose Color Transmit positive TX+ Blue/White Transmit negative TX- Blue Receive positive RX+ Orange/White Receive negative RX- Orange Shield Bare Wiring | GO XSE Installation Manual...
The Auto Select option looks for all sources connected to the device. If more than one source is available for each data type, selection is made from an internal priority list. This option is suitable for the majority of installations. Software Setup | GO XSE Installation Manual...
Page 34
In order to enable group selection, the display must be set to Simrad group. Devices with the Group set to None can be set to use different sources to those of the rest of the network devices. Software Setup | GO XSE Installation Manual...
Selecting a device in this list will bring up additional details and actions: All devices allow allocation of an instance number in the Configure option. Set unique instance numbers on any identical devices on Software Setup | GO XSE Installation Manual...
Display (backlighting), Units (metric or imperial units of measure), Damping (to dynamic data), and Alarms can be grouped either in Simrad group, or groups 1 through to 6. If any of the settings require discrete control, set it to none.
Calibration An offset (positive or negative) can be applied to correct inaccuracies in boat speed, sea temp, air temp, barometric pressure, and depth sourced from NMEA 2000. Software Setup | GO XSE Installation Manual...
0.3 m (1 ft), it will be input as (plus) 0.3 m (1 ft). A setting of 0 (zero) causes the depth displayed to be the distance from the transducer to the bottom. Software Setup | GO XSE Installation Manual...
Page 39
Before setting the offset, measure the distance from the transducer to the lowest point of the boat in the water or from the transducer to the water surface. Software Setup | GO XSE Installation Manual...
Page 40
For example, if the average water speed reads 8.5 knots (9.8 MPH) and SOG records 10 knots (11.5 MPH) the calibration value needs to be increased to Software Setup | GO XSE Installation Manual...
Page 41
ForwardScan installation Available when the ForwardScan feature is turned on. For installation and setup information, refer to the separate ForwardScan documentation. Software Setup | GO XSE Installation Manual...
In a system with more than one radar, the correct device to configure can be selected from this menu. Ú Note: Radars that support dual radar mode are represented twice in the source list, with an A and B suffix. Software Setup | GO XSE Installation Manual...
Page 43
Device ID. With the radar connected and powered up, select the Reset Device ID button to resolve this problem. Software Setup | GO XSE Installation Manual...
Page 44
This is to align the heading marker on the screen with the center line of the vessel. This will compensate for any slight misalignment of the scanner during installation. Any inaccuracy will be evident when using MARPA or chart overlay. Software Setup | GO XSE Installation Manual...
Page 45
Traverse the area again and readjust if sidelobes returns still occur. Exit the dialog. Radar sector blanking (Halo radar only) Radar installed in close proximity to a mast or structure could cause unwanted reflections or interference to appear on the radar image. Software Setup | GO XSE Installation Manual...
Page 46
Interference from some onboard sources can interfere with the Broadband radar. One symptom of this could be a large target on the screen that remains in the same relative bearing even if the vessel changes direction. Software Setup | GO XSE Installation Manual...
"Data source selection" on page 33. Vessel setup The Vessel setup dialog must be used to select the number of engines, the number of tanks and vessel’s total fuel capacity across all tanks. Software Setup | GO XSE Installation Manual...
Page 48
Location to match the engine the device is connected to. Unconfigure - defaults the device which clears all user settings. Reset Fuel Flow - restores only the Fuel K-Value setting, if set in Calibrate. Only Navico devices can be reset. Software Setup | GO XSE Installation Manual...
Page 49
Set to full option selected. Select the Calibrate option. Set the actual amount used based on amount of fuel added to the tank. Select OK to save settings. The Fuel K-Value should now show a new value. Software Setup | GO XSE Installation Manual...
Page 50
A maximum of 5 tanks is supported using Fluid Level devices. Ú Note: Tank data that is output by a compatible engine gateway can also be displayed, however tank configuration for such a data source is not possible from this unit. Software Setup | GO XSE Installation Manual...
Dipswitch setting. The functionality of the CZone system is determined by the CZone Config File which is stored on all CZone modules and the GO XSE. The file is created using the CZone Configuration Tool, a specialized PC application available from BEP Marine Ltd, and associated CZone distributors.
Enabling this causes the GO XSE to synchronize its backlight setting with that of any CZone Display Interfaces set up to share backlight settings. Ú Note: CZone Config also needs to have the GO XSE set as a controller. Wireless setup The unit includes built-in wireless functionality that lets you: •...
Page 53
The MFD's display is shown on the smartphone. To change the MFD's display on the smartphone, use the MFD to change the display on the MFD. The display change on the MFD is reflected on the smartphone. Software Setup | GO XSE Installation Manual...
Page 54
Only visible if the internal wireless is in Client Mode when the device is selected. Shows a list of all networks (hotspots) available for connection. Select the name of the desired network to enter its network key and connect to it. Software Setup | GO XSE Installation Manual...
Page 55
RF device transmitting in the same frequency band. Restore defaults Deletes all user made changes, and restores the wireless to factory settings. Advanced Tools are available within the software to assist in fault-finding and setting up the wireless network. Software Setup | GO XSE Installation Manual...
Page 56
The application must be installed on and run from a tablet device. The GO XSE must be running Iperf server before initiating the test from the tablet. On exiting the page, Iperf automatically stops running.
When the features are enabled, the display may prompt the user for some basic configuration information. Refer to the VesselView® manual or engine supplier for further information. Software Setup | GO XSE Installation Manual...
Updates can be found on the website: www.simrad-yachting.com When the unit is connected to the internet, a pop-up can appear advising that a software update is available and encourages you to download the update.
Page 59
This is the format most used on the web that shares among most GPS systems in the world. Use this format if you are taking data to a competitor's unit. Northstar.dat (no Tracks) • Used to transfer data to a legacy Northstar device. Software Setup | GO XSE Installation Manual...
NMEA 2000 device upgrades The update file must be loaded to the root directory of a memory card inserted in the card reader. Select the Files toolbar option and select the update file under Memory card. Software Setup | GO XSE Installation Manual...
Page 61
If no device is shown, check that the device to be updated has power, and run any outstanding updates for the unit first. Select the device and initiate the upgrade. Do not interrupt the upgrade process. Software Setup | GO XSE Installation Manual...
7 to 9 pin transducer adapter 9" unit accessories Part number Description 000-13698-001 Sun cover 000-13699-001 Panel mount kit 000-13702-001 U-bracket 000-13700-001 Bezel replacement 000-00128-001 Power cable 000-13313-001 7 to 9 pin transducer adapter Accessories | GO XSE Installation Manual...
Page 63
12" unit accessories Part number Description 000-14147-001 Sun cover 000-14246-001 Panel mount kit 000-14148-001 U-bracket 000-14247-001 Bezel replacement 000-00128-001 Power cable 000-13313-001 7 to 9 pin transducer adapter Accessories | GO XSE Installation Manual...
127493 Transmission Parameters, Dynamic 127503 AC input status 127504 AC Output Status 127505 Fluid Level 127506 DC Detailed Status 127507 Charger Status 127508 Battery Status 127509 Inverter Status 128259 Speed, Water referenced 128267 Water Depth Supported data | GO XSE Installation Manual...
Page 65
129810 AIS Class B “CS” Static Data Report, Part B 130074 Route and WP Service - WP List - WP Name & Position 130306 Wind Data 130310 Environmental Parameters 130311 Environmental Parameters 130312 Temperature 130313 Humidity 130314 Actual Pressure Supported data | GO XSE Installation Manual...
Page 66
129539 GNSS DOPs 129540 GNSS Sats in View 130074 Route and WP Service - WP List - WP Name & Position 130306 Wind Data 130310 Environmental Parameters 130311 Environmental Parameters 130312 Temperature 130577 Direction Data Supported data | GO XSE Installation Manual...
7" unit 12 W (900 mA @ 13.5 V) 9" unit 12 W (900 mA @ 13.5 V) 12" unit 20 W (1500 mA @ 13.5 V) Environmental Operating temperature range -15°C to +55°C (+5°F to +131°F) Technical specifications | GO XSE Installation Manual...
Page 68
Weight (display only) 5" unit 0.53 kg (1.16 lbs) 7" unit 0.91 kg (2 lbs) 9" unit 1.32 kg (2.9 lbs) 12" unit 2.22 kg (4.90 lbs) Mounting type Bracket (supplied) or panel mount Technical specifications | GO XSE Installation Manual...
94.0 mm 94.0 mm (3.70”) (3.70”) 117.5 mm (4.62”) 7" unit dimensional drawings 8.0 mm 197.0 mm 74.7 mm (0.32”) (2.94”) (7.76”) 202.2 mm 61.9 mm (7.96”) (2.44”) 220.0 mm 126.9 mm (8.66”) (5.00”) Dimensional drawings | GO XSE Installation Manual...
(3.54”) (0.31”) 263.0 mm 24.0 mm (10.35”) (0.94”) 79.0 mm (3.11”) 12" unit dimensional drawings 8.0 mm 310.0 mm 74.7 mm (0.32“) (12.20“) (2.94“) 323.5 mm 95.0 mm (12.74“) (7.74“) 110.6 mm (4.36“) Dimensional drawings | GO XSE Installation Manual...
Need help?
Do you have a question about the GO XSE and is the answer not in the manual?
Questions and answers