Power Control unconnected
Device will turn on and off when the power button on the front of
the unit is pressed. Leave the yellow Power Control wire
disconnected and tape or heat-shrink the end to prevent shorting.
1
Power cable connector to unit
2
Positive wire (red)
3
Ground wire (black)
4
Power control wire (yellow)
5
Alarm wire (blue)
Power Control to supply positive (auto on)
Device will turn on immediately when power is applied. Common
the yellow wire with the red wire after the fuse.
Ú Note:
The unit cannot be powered down by power button, but
can be put in to standby mode. (The screen backlight turns off.)
Wiring
| GO XSE Installation Manual
2
3
4
+ _
5
2
4
3
+ _
5
1
1
25
Need help?
Do you have a question about the GO XSE and is the answer not in the manual?
Questions and answers