Configuring GIR (Cisco NX-OS Release 7.3(0)N1(1))
switch# configure maintenance profile normal-mode
Enter configuration commands, one per line. End with CNTL/Z.
switch(config-mm-profile)# vpc domain 1
switch(config-mm-profile-vpc-domain)# no shutdown
switch(config-mm-profile-vpc-domain)# exit
switch(config-mm-profile)# no system interface shutdown
switch(config-mm-profile)# end
Exit maintenance profile mode.
switch#
switch# show maintenance profile
[Normal Mode]
vpc domain 1
no shutdown
no system interface shutdown
[Maintenance Mode]
vpc domain 1
shutdown
system interface shutdown
Note
Use the fex-group name command to create a FEX group. Use the fex range command to add or remove
a FEX from the FEX-group. Use the system fex-group name shutdown command to shut down a FEX
group. Use theno system fex-group name shutdown command to bring up a FEX group
This example shows how to create a maintenance mode profile and normal mode profile for upgrading vPC
with FEX (refer topology below):
N5K-1 configuration:
switch# configure terminal
switch(config)# configure maintenance profile maintenance-mode
OL-31641-01
Cisco Nexus 5600 Series NX-OS System Management Configuration Guide, Release 7.x
Configuration Examples for GIR