Setup

Set Power Jumpers

1. Find the red power jumpers for the terminal blocks
supplied in a plastic bag in the circuit box. For haz-
ardous location models, are in the explosion proof
box (E1).
2. For 200-240 VAC and 350-415 VAC, 3 Phase instal-
lations only, use pliers to install the three red power
jumpers into the terminal blocks in the correct posi-
tions as shown in the following illustration. Push
jumpers firmly into position.
F
. 12: Non-Hazardous Location Models
IG
F
. 13: Hazardous Location Models
IG
3. Close junction box cover.
20

Connect Air Supply

Connect air supply line to the 1 in. npt(f) air supply ball
valve inlet.
NOTE:
Use a 3/4 in. (19.1 mm) ID minimum air hose.
E
NOTE:
Air supply requirement: 150 psi (1.0 MPa, 10.3 bar)
maximum; 80 psi (552 kPa, 5.5 bar) minimum (while
running).
Flow volume required: 100 scfm (2.8 m
250 scfm (7.1 m
sure and flow rate are directly related to available air
volume. A typical single gun XM PFP application will use
125 to 175 scfm (3.5 to 5.0 m
ti27667a
NOTE:
Dosing valves are operated by air. The sprayer will not
operate correctly if the inlet air pressure drops below
80 psi (552 kPa, 5.5 bar) while spraying.
ti27668a
ti20105a
3
/min) minimum;
3
/min) maximum. Available fluid pres-
3
/min).
3A2776H