4. Locate the temperature sensor with black heat
shrink sheath and a connected cable that is
tie-wrapped to the B heater power cable.
a. Cut the temperature sensor loose from the tie
wrap.
b. Insert the sensor down inside the hose bundle
so it is buried in the insulation and up against
the fluid hoses. Be sure the sensor cable will not
get pulled tight by the hose.
F
. 22
IG
c. Use electrical tape to wrap the hose bundle
from where it connects to the system to the
hose sheath. This insulates and protects the
hose bundle.
3A2776H
Connect the Fluid Hose Bundle
to the Mix Manifold
1. Unroll the hose bundle out to the spray area.
2. System 262869: Connect the 3/4 in. A and 1/2 in. B
F
3. Remove the U-shaped tube connectors only from
ti20274a
4. Route the purple flush hoses from the manifold
5. Use electrical tape to wrap the hose bundle from
hoses to the material inlet ball valves on the mix
manifold. See F
. 23.
IG
System 24W626: Change the B side inlet nipple
and connect the 3/4 in. A and 3/4 in. B hoses to the
material inlet ball valves on the mix manifold. Color
code material hoses (green and blue) with respec-
tive color identification on mix manifold. See F
Material Inlets
Flush Inlet
. 23
IG
the end of the longer set of red and blue tubes. Trim
the excess tubing to fit the one set of the red and
blue tubes fully into the two brass compression fit-
tings on the aluminum heat circulation plate under
the main manifold. Tighten the compression fittings.
underneath the manifold carriage and connect to
the 1/4 in. flush hose in the hose bundle.
See F
. 23.
IG
where it connects to the system to the hose sheath.
This insulates and protects the hose bundle.
Setup
. 23.
IG
ti20088a
25