Enable Setup Screens
Use these screens to enable and disable functions,
screens, and USB download log files. Checked boxes
indicate the function, screen, or log file is enabled. Refer
to the following table for details.
To enable and disable functions, screens, and USB log
files, press
from the Home Setup screen. Once
in the Enable Setup screen, press
scroll through each subscreen. Press
scroll through each field within the subscreens, and
press
to enable or disable each. Press
return to the Home Setup screen.
Icon
Function
USB data download function. Disable this
function to prevent operators from chang-
ing USB settings.
NOTE: Even if this function is disabled,
selected USB logs will still be downloaded.
Enable or disable totalizer screens.
Enable or disable batch totalizer clear func-
tion.
Display potlife timer on all screens.
Enable or disable potlife timer setup
screen.
Display flow rates on run screens
Display A and B pressures on run screens.
Display A and B heater outlet temperatures
on run screens.
Enable or disable ability to change meter-
ing pump size in system setup screens.
Enable or disable ratio screen. If enabled,
ratio screen will automatically display after
sprayer runs for 10 seconds.
Enable or disable pump maintenance setup
screens.
3A2776H
Icon
and
to
and
to
to
Fast Dosing Function
Fast Dosing
Enable Setup Screen 1
(Shown with factory default settings.)
Appendix A - User Interface Display
Function
Enable or disable dosing valve mainte-
nance setup screen.
Enable or disable incoming air filter mainte-
nance setup screen.
Enable or disable limits (pressure and tem-
perature) screens.
Fast dosing function. Enable function to
minimize B side dose size and increase
dosing rate. See table below.
Use this function with short integration
hose. The system will attempt to hold the
dosing sizes below the advisory level.
Display time on all screens.
Enable or disable downloading individual
USB log files (1-4).
Enable or disable the A or B feed system.
When disabled, that feed system will not be
shown on the user interface and no alarms
will be generated for that feed system. This
enables the user to use the air shutoff
valve on the feed pump to turn on and off
the feed pumps if there is a problem with
the feed system.
Selects system ratio by volume
by weight
mode. Only one of these
modes can be enabled at one time.
Advisory QTAE
ON
20 cc
OFF
35 cc
or ratio
Alarm QDAE
30 cc
45 cc
73