Installation; Power Supply; Connect Power - Graco 25M480 Instructions Manual

Yuhong electric driver for high pressure airless sprayer
Table of Contents

Advertisement

Installation

Improper wiring may cause electric shock or other
serious injury. All electrical wiring must be done by a
qualified electrician and comply with all local codes
and regulations.

Power Supply

See Table 1 for power supply requirements. The system
requires a dedicated circuit protected with a circuit
breaker.
Table 1: Power Supply Specifications
Voltage
Phase
200-240 VAC
Select the minimum cord wire gauge based on length
according to the table below:
Length
50 ft (15.24 m)
100 ft (30.48 m)
200 ft (60.96 m)
300 ft (91.44 m)

Connect Power

1. Cut power cord wires to the following lengths:
-
Ground wire - 6.5 inches (16.5 cm)
-
Power wires - 3.0 inches (7.6 cm)
-
Add ferrules as necessary. See F
POWER
F
. 1: Power Cord
IG
3A5173A
Hz
Current
1
50/60
20 A
2
Gauge
mm
12 AWG
3.31
10 AWG
5.26
6 AWG
13.29
4 AWG
21.14
. 1.
IG
GROUND
2. Bring cord to unit and remove four screws to
separate junction box cover (G) with power switch
(E) from remainder of sprayer. See F
F
. 2: Power Switch
IG
3. With power switch (E) and junction box cover (G)
detached from machine, wires inside junction will
appear as below.
NOTE: Two wires will be installed in terminals 1L1
and 5L3. See F
. 3.
IG
NOTE: Press gasket against back sealing face of
junction box to ease installation of power cord.
C2
F
. 3: Terminal Connections
IG
4. Insert power cord (from step 1) through cord grip
(C2) and into junction box (S).
NOTE: Power wires should be installed into
terminals 2T1 and 6T3. See F
Installation
. 2.
IG
S
G
E
G
. 3:
IG
5