Appendix B - Alarms
Alarm
Code
Alarm Problem
DEAX
Pump Does Not Move In 10
DEBX
Minutes.
DFAX
Pump Did Not Stall Against
DFBX
Fluid Pressure On Up Stroke
Only.
DGAX
Pump Did Not Stall Against
DGBX
Fluid Pressure On Down
Stroke Only.
DJAX
Pump Motor Linear Sensor
DJBX
Has No Signal.
Pump Motor Linear Sensor Is
Out Of Range.
DKAX
Pump Motor Reed Switch
DKBX
Failure; Missing Signals From
One Or Both Switches.
F6AJ
A Air Motor Linear Sensor
Jump Advisory.
F6AK
A Air Motor Reed Switch Sig-
nal Missing Advisory.
F6BJ
B Air Motor Linear Sensor
Jump Advisory.
F6BK
B Air Motor Reed Switch Sig-
nal Missing Advisory.
F7AX
System Detects Unexpected
F7BX
Pump Movement (Fluid
Flow).
F8RX
No movement occurred in cir-
culation mode
90
When
Active
Park or
Recirculation valves were not
Pump Test
opened to allow flow.
Pump Test Pump piston check valve, piston
packings, or dosing valve are not
holding fluid pressure.
Pump Test Pump inlet check or dose valve is
fouled, or damaged.
Always
No linear sensor signal from motor.
Linear sensor plugged in while
power is on.
Bad connection inside fluid control
module.
Always
Linear sensor is beyond range.
Sprayer is not properly grounded.
Always
Bad motor cable connections, or
bad reed switch.
Reed switch cable is plugged in
while power is on.
Bad connection inside fluid control
module.
Always
System ran out of fluid.
Linear sensor is bad.
Always
Reed switch does not see the air
motor magnet.
Reed switches are bad.
Air motor is icing.
Always
System ran out of fluid.
Linear sensor is bad.
Always
Reed switch does not see the air
motor magnet.
Reed switches are bad.
Air motor is icing.
Spray
Recirculation valve or dosing valve
open or leaking for more than five
seconds.
Circulation Pump did not move for 5 seconds
while in circulation. User may have
attempted to spray in circulation
mode.
Cause
Open recirculation valves.
Flush pump. See General Tips,
page 63. Recheck. Remove, clean,
and repair lower. See XM PFP
repair manual.
Remove inlet housing & clean and
inspect. See XM PFP repair manual.
Swap A and B sensors. Replace
sensor if problem follows sensor.
See XM PFP repair manual.
Power sprayer off and back on. Do
not plug in linear sensor while power
is on.
Replace fluid control module. See
XM PFP repair manual.
Replace sensor or sensor magnet.
See XM PFP repair manual.
See Grounding, page 19.
Swap A and B motor cables.
Replace cable if problem persists.
Otherwise replace reed sensor
assembly. See XM PFP repair man-
ual.
Power sprayer off and back on. Do
not plug in reed switch cable while
power is on.
Replace fluid control module.
Add fluid to the system.
Replace linear sensor.
Replace air motor reed switch mag-
net.
Replace air motor reed switch. Pre-
vent air motor icing. See advisory
P9AX and P9BX.
Add fluid to the system.
Replace linear sensor.
Replace air motor reed switch mag-
net.
Replace air motor reed switch. Pre-
vent air motor icing. See advisory
P9AX and P9BX.
Close or repair recirculation valve,
and run Pump Test. See Pump and
Metering Test and Calibration for
Ratio by Weight Mode, page 48.
Use spray mode for spraying.
Solution
3A2776H