Setup

Location

Select a location that complies with the approval rating
for your model. For approval rating, see Models, page
3.
The location must have the required power and air sup-
ply to set up your sprayer. See Technical Data, page
96, for Air Consumption and Power Requirements Main-
tain access from all sides.

Unboxing

The machine is shipped on two separate pallets, one
with the XM PFP and one with the two feed modules.
Each pallet is wrapped in heavy cardboard with a lid
secured with straps. Cut the lid straps then remove the
lids and cardboard.
Front to Back Configuration
F
. 9
IG
3A2776H

Ratio Configuration

Proportioners leave the factory set up for materials
which are higher volume and/or viscosity on the "A"
side, and lower volume and/or viscosity on the "B" side.
1:1 mix ratio machines will normally change the "B" side
circulation return hose from 3/8 in. to 1/2 in. ID to bal-
ance the recirculation speeds.
1:1 mis ratio machines also use outlet hose bundles
which are 3/4 in. on both sides. The outlet fittings on the
machine and the inlet fittings on the mix manifold must
be changed on the "B" side from 1/2 in. to 3/4 in.
1:1 Ratio Adapter Kit 24X461 is provided with your
machine. Install the kit, if necessary, before screwing
the modules together.

Configuration Options

The system can be laid out two ways:
Side by side: where the feed modules are on either
side of the system module
Front to back: where the feed modules are behind
the system module
ti20267a
Side by Side Configuration