Graco XM PFP Repair Parts

Plural-component sprayer
Hide thumbs Also See for XM PFP:

Advertisement

Repair - Parts
XM
PFP
Plural-Component Sprayer
For spraying two-component passive fire protection (PFP) intumescent epoxies. For
professional use only.
Important Safety Instructions
Read all warnings and instructions in this
manual and in all supplied manuals. Save
all instructions.
See page 3 for model information, including
maximum working pressure and approvals.
3A2989V
EN

Advertisement

Table of Contents
loading

Summary of Contents for Graco XM PFP

  • Page 1 Repair - Parts ™ 3A2989V Plural-Component Sprayer For spraying two-component passive fire protection (PFP) intumescent epoxies. For professional use only. Important Safety Instructions Read all warnings and instructions in this manual and in all supplied manuals. Save all instructions. See page 3 for model information, including maximum working pressure and approvals.
  • Page 2: Table Of Contents

    Graco Standard Warranty ....86 Graco Control Architecture Module Pro 3A1244 Graco Information ......86 gramming 334939...
  • Page 3: Models

    Models Models Ratio System Series Location Range Approvals Not for use in explosive atmospheres or hazardous locations. 1:1 to 24W626 1.5:1 Non-Hazardous 1.5:1 to 262869 9902471 Certified to CAN/CSA C22.2 No. 88 Conforms to UL 499 1:1 to 262945 1.5:1 9902471 Certified to CAN/CSA C22.2 No.
  • Page 4: Warnings

    • For information on the required dimensions of the flameproof joints contact the holder of this certifi cate (Graco Inc.). Flame-path joints are not intended to be repaired. • Special fasteners for securing equipments covers on the flameproof heaters shall have a minimum yield strength of 1,100 MPa and be corrosion resistant and sized M8 x 1.25 x 30.
  • Page 5 Warnings WARNING WARNING WARNING WARNING SKIN INJECTION HAZARD High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment. •...
  • Page 6: Keep Components A And B Separate

    Component Identification WARNING WARNING WARNING WARNING PERSONAL PROTECTIVE EQUIPMENT Wear appropriate protective equipment when in the work area to help prevent serious injury, including eye injury, hearing loss, inhalation of toxic fumes, and burns. Protective equipment includes but is not limited to: •...
  • Page 7: Pressure Relief Procedure

    BYPASS TI19265a2 2. If the system will be shut down for more than a few hours, perform Park Fluid Pump Rods procedure in XM PFP Operation manual to prevent fluid hard ti20127a ening on the pump shaft. 3. Press (Stop button).
  • Page 8 Pressure Relief Procedure 7. Open recirculation ball valves. 11. Close mix manifold material ball valves. ti20129a 12. Perform Flush Mixed Material procedure in XM PFP Operation manual to prevent mixed material curing in the system and to relieve pressure in the 8.
  • Page 9: Flush Mixed Material

    Flush Mixed Material Flush Mixed Material 8. Open flush pump air supply valve (CB). Pull out and slowly turn flush pump air regulator (CG) clockwise to increase air pressure. Use lowest pressure needed to flush material out of hose. To avoid fire and explosion: •...
  • Page 10: Troubleshooting

    Troubleshooting 13. Close flush ball valves. ti20095a ti20095a 14. Use a rag and solvent to clean spray tip then rein stall on gun. 15. Remove the static mixer. Clean the mix element then re-install the mixer. Troubleshooting See sprayer Setup - Operation manual for troubleshoot ing details.
  • Page 11: Repair

    Repair Repair Control Air Regulator Filter 2. Remove four nuts (21) and then remove front and rear shrouds (19, 20). Follow Pressure Relief Procedure on page 7 if service time may exceed pot life time, before servicing fluid components, and before transporting sprayer. Replace Air Filter Element There are two air filters on all systems: the inlet air regu lator filter on the air controls and the main air inlet mani...
  • Page 12 Repair Main Air Inlet Manifold Filter 2. Unscrew filter bowl collar from main air inlet filter (14). ti199526a1 3. Remove and replace filter element (701a). See Air Filter (24P899), page 73. 4. Reassemble filter bowl. Purge Box Air Inlet Filter 1.
  • Page 13: User Interface/Control Box

    Repair User Interface/Control Box Replace Single Solenoid Module 1. Remove Shroud and Front Panel of Control Box, see page 13. 2. Disconnect solenoid cable connector (542) from the solenoid (509a) being replaced. See Electrical Schematics if necessary. For hazardous location Remove Shroud and Front Panel of Control systems see Sensors Schematic Control Box on page 43.
  • Page 14 7. Most of the system configuration is stored in the FCM. Use the display to change the configuration to 2. Disconnect CAN cables and USB cable from USB the values in the old FCM. See XM PFP operation module (519). manual for instructions.
  • Page 15 Repair Display Replace Display Replace Display Battery To prevent fire and explosions, do not replace the dis To prevent fire and explosions, do not replace the dis play in a hazardous location. play battery in a hazardous location. NOTE: Order display kit (504) for replacement. NOTICE NOTICE To avoid damaging circuit board, wear a grounding...
  • Page 16 14. Load software. See Upgrade Software, page 16. 10. Reinstall shrouds and front panel. 15. Replace shroud. 16. Configure system settings as they were set on old display. See XM PFP Operation manual for instruc tions. Replace Front Panel See Replace Display, page 15, for instructions.
  • Page 17: Junction Box

    Repair Junction Box Replace Fluid Control Module Cube (FCM3, ref. 408) Ground screw Replace High Power Temperature Control Module (HPTCM, ref. 435) ti26763 1. Turn system main power switch OFF. 2. Open junction box. 3. Unplug all connections on the FCM3. 4.
  • Page 18: Purge Box

    Repair Purge Box Replace Fluid Control Module Cube (FCM3, ref.1547) Replace High Power Temperature Control Module (HPTCM, ref. 1535) Ground screw 1. Turn system main power switch OFF. 2. Open the purge box and remove the purge control ler (not shown) to access the FCM mounting screws.
  • Page 19 Repair Replace Purge Controller 3. Remove seven mounting screws (S), door (D), and door gasket (G). Remove the purge controller For hazardous location systems only. (1504) and gasket (1549) from the back of the purge box. 1. Turn system main power switch OFF. 4.
  • Page 20 Repair Multi-zone 3 Channel Barrier 1. Turn main power off. 2. Open purge box. 3. Disconnect CAN cables, ground wire (1527), and air tubing from fittings. power wires 1527 1526 1516 1523 4. Disconnect red and black power wires from terminal blocks.
  • Page 21: Air Controls

    Repair Air Controls Replace Flush Pump Air Regulator (625) 1. Remove Air Control Assembly (18). Remove Control Box Shrouds 2. Remove regulator nut (631), and disconnect air 1. Close main air shutoff valve on air supply line and lines (632, 633) running to regulator (625). See F on system.
  • Page 22 Repair Replace Solenoid Inlet Air Regulator (644) 8. Follow steps in reverse order to reassemble. 1. Remove Control Box Shrouds. 9. Set new air pressure regulator to at least 80-85 psi (0.55-0.58 MPa, 5.5-5.8 bar). 2. Remove Air Control Assembly (18). Replace Purge Box Inlet Air Regulator (160) 3.
  • Page 23: Dosing Valve Assembly

    Repair Dosing Valve Assembly 1. Follow Pressure Relief Procedure, page 7. 6. Remove dosing valves. 2. Disconnect all fluid lines from dosing valves (28 or 7. See Ratio Control Valve Assemblies (28, 29) on 29). See F . 6. page 74 for disassembly illustration. 3.
  • Page 24: Sensors

    Repair Sensors 5. Close insulation and hose bundle wrap and re-tape. Ensure there is no stress on the cable. 6. Reconnect M8 connector. Replace Temperature (RTD) Sensors Replace Fluid Pressure Sensor This procedure applies to: 1. Close main air shutoff valve on air supply line and •...
  • Page 25: Pump Assembly (System Module)

    Repair Pump Assembly (System Remove Displacement Pump Module) Follow these instructions for removing only the displace ment pump; the air motor will remain installed. 1. Follow Pressure Relief Procedure, page 7. 2. Close ball valve on tank outlet. Prior to servicing the pump assembly you must first 3.
  • Page 26: Pail Feed Ram Pump Assembly (Feed Module)

    Repair Flush Pump Remove Air Motor 1. Follow Pressure Relief Procedure, page 7. 2. Disconnect displacement pump from air motor. See steps 2 and 3 under Remove Displacement Pump, page 25. 1. Follow Pressure Relief Procedure, page 7. 3. Disconnect sensor cable, air line, and ground wire from air motor.
  • Page 27: Heaters

    Repair Heaters Replace 1. Wait for heaters to cool before replacing the heat ers. 2. Follow Pressure Relief Procedure, page 7. 3. Turn off power. NOTE: See applicable heater manual for wiring, repair, and parts information. See Warnings on page 4. 4.
  • Page 28: Replace Radar Level Sensor

    Repair Replace Radar Level Sensor NOTE: Order radar level sensor kit 24X090. See Feed 7. Feed the rod into the sensor head and screw the Modules on page 56 for kit contents. threaded end into the sensor head. 8. Use a wrench to hold the 3/8 in. flats on the sensor NOTE: Tank level sensors changed in 2014.
  • Page 29: Set Up A New Radar Level Sensor

    Repair Set Up a New Radar Level Sensor Level sensors need to have three settings setup after installing on the tank of the PFP machine. The tank must be empty, or the level needs to be at least below the bottom of the installed probe with the tank cover closed. 1.
  • Page 30 Repair 4. Set FULL CAL to .691 meters. a. Press + to get to FULL CAL, then press E. b. Press + until decimal point (.) appears, then press E. c. Press + until 6 appears, then press E. d. Press + until 9 appears, then press E. e.
  • Page 31: Electrical Schematics

    Electrical Schematics Electrical Schematics Non-Hazardous Location Schematic AC Power Schematic SW1-2 TB12 SW1-4 TB12 TB12 TB11 TB11 TB11 15U423 TB10 TB10 TB10 SW2-1 SW2-2 SW2-3 SW2-4 15U423 CB5-3 CB5-4 CB5-1 CB5-2 CB4-3 CB4-4 CB4-1 CB4-2 HTR-A-CB3-4 CB3-3 CB3-4 CB3-1 CB3-2 HTR-A-CB3-2 CB2-3 CB2-4...
  • Page 32 Electrical Schematics Heater Schematic Hose RTD 24P242 Extension 125357 Splitter 125806 TCM-H-RTD TCM-B-RTD Heater RTD 126427 TCM-A-RTD Compression Cord Grip Fitting 126351 121603 Cord Grip 121603 24Y437 HTR-H-PWR RTD Cable 126511 RTD Cable 126511 White Black TCM-H-PWR White Black TCM-B-PWR White Black TCM-A-PWR...
  • Page 33 Electrical Schematics CAN Network Schematic CAN Cable 125789 CAN-FCM1-2 CAN-FCM1-1 Green Com Label Blue Com Label CAN Power Cable 24R735 Yellow Circle Label TB12 TB12 TB11 TB11 TB10 TB10 PS1-V- Orange Square Label 3A2989V...
  • Page 34 Electrical Schematics Sensor Schematic Junction Box 262856 Solenoid Cable 121806 Sol A SOL-A Sol B SOL-B Solenoid Cable 121806 Tank Level B Cable 126494 Cord Grip Tank Level A 120858 Cable 126494 Nut 120859 Level Sensor 24X090 Level Sensor 24X090 3A2989V...
  • Page 35 Electrical Schematics Sensors Schematic Control Box 18 AWG Copper Wire Door Ground Pressure Sensor B 15M669 Wire 15B090 O-Ring 121399 USB Extension Cable 15R324 Reed Switch B 119700 Cover 15R325 Linear Sensor B 256893 Air Motor B Cable 15U542 Extension Tank RTD B 126381 Junction Box NXT411 Cable 121683...
  • Page 36 Electrical Schematics Non-Hazardous XM PFP Air Logic Schematic 3A2989V...
  • Page 37 Electrical Schematics Feed Module Air Controls Schematic Non-Hazardous Location 3A2989V...
  • Page 38: Hazardous Location Schematics

    Electrical Schematics Hazardous Location Schematics AC Power Schematic Explosion Proof Box TB10 TB12 TB13 TB15 Bushing Purge Box 17B984 Input Power Power Connection 200-240 VAC Delta GND - TB1 L1 - TB3 L2 - TB4 L3 - TB5 350-415 VAC Wye GND - TB1 L1 - TB2 L2 - TB3...
  • Page 39 Electrical Schematics AC Power Schematic Purge Box SW2-2 Switch SW2 SW2-4 15U423 SW3-2 Tank Heater Switch SW3 15U423 SW3-4 Flush Heater SW2-3 SW2-1 Power Supply 126453 Surge Protector 16U530 HTR-H-CB1-2 HTR-H-CB1-4 HTR-B-CB2-2 HTR-B-CB2-4 HTR-A-CB3-2 HTR-A-CB3-4 GND-3 3A2989V...
  • Page 40 Electrical Schematics Heater Schematic Purge Box RTD Cable 24W680 HTR-B-RTD TCM-B-RTD RTD Cable 24W680 TCM-A-RTD Heater Cable 24W678 17C685 Cable Gland Cord Grip Black 16M826 Black 238909 TCM-B-PWR Pail Ground Black 14 AWG Copper Wire TCM-A-PWR 24W678 Flush Pump Ground HTR-A-PWR 18 AWG Copper Wire TCM-A-GND...
  • Page 41 Electrical Schematics CAN Network and DC Power Schematic 18 AWG Copper Wire Multi-Zone Power Supply IS Barrier and Isolators Ground Wire 24W610 DIN Rail 17D228 194337 17D226 Hose TL-15 TL-14 Tank Level 17D227 126453 PS1-GND PS1-V+ PS1-V- TB19 TB19 TB19 TB18 TB17 TB17...
  • Page 42 Electrical Schematics Sensors Schematic Purge Box Tank Level B Cable 17D198 Tank Level A Cable 17D197 Hose Bundle RTD Cable 17D199 Hose Heater RTD Cable 17D200 HR-7 Hose Tank Level TL-9 Level Sensor 24X090 Fluid Control FCM-1 289696 Base 289697 Level Sensor 24X090 17C056...
  • Page 43 Electrical Schematics Sensors Schematic Control Box 18 AWG Copper Wire Door Ground Pressure Sensor B 15M669 Wire 15B090 O-Ring 121399 USB Extension Cable 15R324 Reed Switch B 119700 Cover 15R325 Linear Sensor B 256893 Air Motor B Cable 15U542 Extension Tank RTD B 126381 Junction Box NXT411 Cable 121683...
  • Page 44 Electrical Schematics Hazardous XM PFP Air Logic Schematic 3A2989V...
  • Page 45 Electrical Schematics Feed Module Air Controls Schematic Hazardous Location 3A2989V...
  • Page 46 Electrical Schematics Hazardous Location Purge Box Air Controls Schematic Box Air Relief Valve 17D465 Elbow 112781 1/8 NPTF Internal Purge Air Pressure - Open External Exhaust Vent 3/8 OD Tubing C12508 Air Supply Air Out Flam Arrester Pressure Switch 17B982 17B983 3A2989V...
  • Page 47: Parts

    Parts Parts Item and Quantity (2a) Ratio Feed Hose Included System Location Range Base System Feed Skid Module Bundle Accessories 1.5:1 to 24Y097 (A) 262869 16T121 24Y098 (B) Non-Hazardous 262878 24P202 1:1 to 24Y097 (A) 24W626 16T122 1.5:1 24Y098 (B) 1.5:1 to --- (NFS) 262943...
  • Page 48: Xm Pfp System Subassemblies

    Parts XM PFP System Subassemblies Non-Hazardous Location Base System (262878) Hazardous Location Base System (262941) Page 1 of 5 96* 61* ti20154a Heated Hose Bundle 16T121 (3/4 x 1/2) included with assemblies 262869 and 262943. Heated Hose Bundle 16T122 (3/4 x 3/4) included with assembly 262945 and 24W626.
  • Page 49 Parts Base System (262878, 262941) page 2 of 5 Set air regulator to 80 psi (550 kPa, 5.5 bar) 262941 hazardous unit only 140a 45, 11 262941 only 4, 5 3A2989V...
  • Page 50 Parts Base System (262878, 262941) page 3 of 5 262941 only 3A2989V...
  • Page 51 Parts Base System (262878, 262941) page 4 of 5 262941 only with heated flush circulation pump 1576 262941 only 3A2989V...
  • Page 52 Parts Base System (262878, 262941) page 5 of 5 24W612 262941 only 262941 only 82 100 245863 24W612 3A2989V...
  • Page 53 0.25 in. ID, 6 ft 117623 NUT, cap, 3/8-16 205418 HOSE, coupled, air, 1/2 x 6 ft LABEL, XM PFP 16P244 HOSE, coupled, air, 5/16 x 3 ft 15T567 NUT, backup plate, hinge 248208 HOSE, coupled, air, 5/16 x 4 ft 15T568 DOOR, control shroud 61...
  • Page 54 Parts Part Description Part Description 16P856 LABEL, codes, alerts; all 115901 TRIM, edge, protection 16T171 STRAP, frame connector languages 100679 SCREW, cap, hex head 125357 CABLE, M8, 4-pin, male/female, 115211 SCREW, cap, hex head 1 meter SCREW, hex head with serrated 126494 CABLE, M12, 5p, 4-wire with drain 126351 FITTING, compression, face flange base, 1/2-13...
  • Page 55 Parts Part Description 167† --- NIPPLE, 3/8 - 1/4 npt x 2.6” 168† 156971 FITTING, nipple short 169† --- FITTING, cap, hex, 1/4 npt(f) 170† 24W678 CABLE, assembly, armored 171† --- BRACKET, air filter 172† 112698 ELBOW, male, swivel 173† 113911 GAUGE, pressure, air 174†...
  • Page 56 Parts Feed Modules Page 1 of 2 B Side Feed Module, 24Y098 A Side Feed Module, hazardous area unit, see items 226 and 325 A Side Feed Module, 24Y097 268, 215 219a 213 211 Turns clockwise as viewed from the top A Side Only 3A2989V...
  • Page 57 Parts Page 2 of 2 B Side only 227a (A) Side only 227c 227b 3A2989V...
  • Page 58 Parts Feed Modules Continued Ref. Part Description Qty. 054172 TUBE, nylon, round Ref. Part Description Qty. 054753 TUBE, nylon, round, black FRAME TUBE, 0.275 in. ID black nylon 24M683 TANK, pressure, assembly 115313 PLUG, tube BOLT, hex head, 3.25 in. long, 126900 FITTING, 1/2 tube x 3/8 npt(m) 5/8-11 215241 HOSE, 3/4 in.
  • Page 59 Parts Ref. Part Description Qty. 117571 GASKET, santoprene 17D307 FITTING, nipple, quick coupling 159239 FITTING, nipple, pipe, reducing 158683 FITTING, elbow, 90 degree 17D024 BRACKET, mount, Viscon Heater 121488 SCREW, hex head, flanged 24Y438 CABLE, assembly, armored, (non-hazardous), (A) side only 24W679 CABLE, assembly, hazardous area (A) side only 126896 ELBOW, 1/2 in.
  • Page 60 Parts Heated Hose Bundle 16T121 - 3/4 in. x 1/2 in. 16T122 - 3/4 in. x 3/4 in. 305 (blue) 310b 310c 302 (red) 310a ti20243a Part Description Part Description 310c 126896 ELBOW, 1/2 in. tube x 1/2 nptf H67550 HOSE, coupled, 3/4 in., 6500 psi; 311...
  • Page 61: Base System (262878, 262941) Subassemblies

    Parts Base System (262878, 262941) Subassemblies System Air Controls Module (255761) NOTE: For Feed Module Air Panel (262860) parts, see page 79. Ref. 27 621 622 640 631 Ref. Part Description Qty. Ref. Part Description Qty. 054760 TUBE, polyurethane, round, black; 1.25 157350 NIPPLE, pipe;...
  • Page 62 Parts Purge Box (Hazardous Area Machines) Page 1 of 4 1561 1562 1563 1558 1576 1557 1556 1576 1564 1576 1560 1564 1558 1565 1556 1531 (ref) 1519 1516 1569 1528 1566 1576 1531 1532 1568 1527 1569 1529 1540 (ref) 1530 1570 1576...
  • Page 63 Parts Page 2 of 4 1527 1576 1523 1516 1525 1523 1522 1516 1504 1523, 1524 1522 1504 1520 1521 1533 1534 1530 1507 1536 1537 1543 1538 1542 1540 1541 1535 1540j 1534 1539 1540k 1540e 1530 1540h 1540g 1540b 1540c 1540d...
  • Page 64 Parts Page 3 of 4 1501 1518 1519 1516 1502 1504 1506 1503 1507 1512 1508 1510 1513 1593 1517 1511 1504 1509 1503 1515 1516 1502 1547 1597 1595, 1596 1504 1594 1545 1504 1553 1553 1546 1504 1544 1552 1504 1549...
  • Page 65 Parts Page 4 of 4 1552 1518 1526 1550 1566 1553 1572 1552 1505 1553 1504 1541 1504 1550 Length Tubing in (mm) 13 (330.2) 35 (889) 1574 26 (660.) 39 (990.6) 1575 30 (762) 3A2989V...
  • Page 66 1501 24W069 ENCLOSURE 1502 15U423 SWITCH, 2P, 25A 1540 24X085 RAIL, purge, circuit breakers; 1503 17D815 LABEL, purge box, XM PFP, haz includes 1540a-1540k 1540a 514014 RAIL 1504 17D465 CONTROL BOX, purge 1540b 120838 BLOCK, clamp end 1505 114332 FITTING, connector, male...
  • Page 67 24R735 CABLE, CAN power, m12 fem, 1570 100307 NUT, hex pigtail 1571 113161 SCREW, flange, hex hd 1590 17D867 LABEL, cord wrap, XM PFP, haz 1572 114109 FITTING, elbow, male, swivel 1573 17D194 CABLE, ground, box, purge 1591 125871 TIE, cable, 7.5 in...
  • Page 68 1566d 17B982 FITTING, arrestor, flame 1566e 17B983 SWITCH, pressure 1566f 24X158 BREATHER, drain 1566g 116876 WASHER, flat 1566h 120039 FASTENER, schs, 10-32 x 1/2 in 1566j 17D816 LABEL, hang tag, XM PFP, haz 1566k 125871 TIE, cable 7.5 in 3A2989V...
  • Page 69 Parts Junction Box (Non-Hazardous Area Machines) 412, 413, 414 (6x) 430, 431 (2x) 416, 417 427, 432 428d 428c 412, 413, 414 (3x) 419, 420 441, 442 414, 429 (2x) 428a 481 482 476 477 480 (4x) (6x) 3A2989V...
  • Page 70 Parts Junction Box (Non-Hazardous Area 115942 NUT, hex, flange head Machines) 24Y169 MODULE, gca, mzhp 17F844 LABEL, ID, multi-zone, lower a b Ref. Part No. Description 17F921 LABEL, ID, multi-zone, upper a b ENCLOSURE, weldment 24R754 CONNECTOR, power, male, 2 pin 120858 BUSHING, strain relief, m40 24U109 CABLE, over-temp, switch short thread...
  • Page 71 Parts Control Box (16) 504b 504f 532 538 504e 504h 504c 504g 504a, 504d 524, 525 519c Ref. Part Description Ref. Part Description BOX, control 505† 262642 KIT, replacement, display; LABEL, control display includes 504 and 506 503† 262641 KIT, replacement, USB; includes 506* 17E110 TOKEN, software 519 and 506...
  • Page 72 --- Not for sale.  Not shown.  Base electronic components do not have XM PFP-specific software installed. Therefore, use software upgrade token (506) to install software before use. † Includes software token (506) and instruction sheet.
  • Page 73 Parts Air Filter (24P899) Apply PTFE tape and/or pipe sealant to all non-swiveling pipe threads. Orient fittings approximately as shown. ti20218a Part Description 16T236 FILTER, air, 1-1/4, auto drain 701a 106204 FILTER ELEMENT C19662 BUSHING, 1-1/4 x 1 npt carbon steel 110300 FITTING, elbow, street, pipe 158585 FITTING, nipple...
  • Page 74 Parts Ratio Control Valve Assemblies (28, 29) 836 1 837 1 840 1 857 1 Apply pipe sealant to all non-swiveling pipe threads. Position valve (832) with barbed fitting (833) oriented as shown, position elbow (837) as shown. ti20219a Torque until nut (831) bottoms out in housing. Flip ball valve handle retainer (855).
  • Page 75: Feed Module Sub-Assemblies

    Parts Feed Module Sub-Assemblies Air Powered Agitator (24P885) Read instr uction man ual. Tag No . 15A722 Re v A Leave a 0.015 in. gap between each half of couplings (910, Apply pipe sealant to all non-swiveling pipe threads. 911, 916, 917). Apply low strength threadlocker.
  • Page 76 Parts Air Powered Agitator (24P885) Part Description 16P919 SHAFT, agitator, upper 16U219 HOUSING, agitator SEAL, 0.875 in. ID x 1.125 in. OD, PTFE SPACER, shaft, agitator, ASME 122774 BEARING, ball, 3/4bore x 1-3/4 dia. x 16P920 HOUSING, bearing, agitator SCREW, socket head set screw, 5/16-18 x 0.75 112222 SCREW, socket cap head RING, retaining, external, 0.750 in.
  • Page 77 Parts Tank Air Manifold Assembly (218) 1008 1012 1001 1011 1010 1004 1002 1005 1013 1003 1009 1008 1013 1003 1007 1006 Apply pipe sealant to all non-swiveling pipe threads. Orient all fittings as shown. Part Description 1001 189016 MANIFOLD, air, inlet 1002 155665 UNION, adapter 1003 156849 PIPE, nipple 1004 214847 LUBRICATOR, air line...
  • Page 78 Parts Static Mixer (16T316) 1303 1301 1302 1303 Apply pipe sealant to all non-swiveling pipe threads. Part Description 1301 --- TUBE, mixer 1302 24P886 MIXER, 12 element, stainless steel 1303 16T315 BUSHING, reducing 3/4 nptf x 1/2 npt 1304 --- SEALANT, pipe, stainless steel --- Not for sale.
  • Page 79 Parts Feed Module Air Panel (262860) NOTE: For System Air Controls Module (255761) parts, see page 61. 1102 1103 1101 1123 1122 1103 1113 1114 1121 1104 1122 1128 1109 1121 1111 1120 1119 1122 1118 1116 1130 1115 1129 1117 1105 Hazardous Area Machines only...
  • Page 80 Parts Air Panel Check Valve (16T481) Part Description 1101 BRACKET, air control 1102 LABEL, instructions 1103 121424 GAUGE, pressure, panel mount, 1.5 in. 1104 15T498 FITTING, 90 degree, swivel, 5/32 in. tee x 1/8 in. female npt 1105 116513 REGULATOR, air 1106 121141 FITTING, elbow, swivel, 3/8 tee, 1/4 in.
  • Page 81: Accessories

    Parts Accessories Flexible Fluid Connection Kit (262820) 1412 Part Description 17G061 BAG, 100 pack, polyethylene, (see 1411 Batch Dispense or Ratio Test in 1401 sprayer Setup - Operation manual) 24P833 KIT, mix wetted parts, contains one set of spare parts from the mix manifold outlet to the spray tip.
  • Page 82: Technical Data

    Technical Data Technical Data XM PFP Metric Ratio Tolerance Range (before alarm) +/- 5% Maximum Flow Rate (measured with oil) 3 gallons per minute 13.6 liters per minute Fluid Viscosity Range Handles mastic materials which are loaded into heated tanks with...
  • Page 83 Technical Data XM PFP Metric Wetted Parts Suction Tube (Flush) Aluminum Tanks Stainless Steel Flush Pump Carbide, PTFE, stainless steel, UHMWPE Hoses Nylon Pumps (A, B and Feed Pail) Carbon steel, alloy steel, 303, 440, 17-ph grades stainless steel, zinc and nickel plating, ductile iron, tungsten carbide, PTFE...
  • Page 84: Dimensions

    Technical Data Dimensions Min: 70 in. (1780 mm) Max: 84 in. (2130 mm) 76 in. 52 in. (1930 mm) (1320 mm) Min: 70 in. (1780 mm) Max: 84 in. (3130 mm) 104 in. (2640 mm) 38 in. (965 mm) 3A2989V...
  • Page 85 Technical Data 3A2989V...
  • Page 86: Graco Standard Warranty

    With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.

Table of Contents