Graco XM 24W626 Operation Manual page 92

Xm pfp plural-component sprayer
Table of Contents

Advertisement

Appendix B - Alarms
Alarm
Code
Alarm Problem
P9AX
A Pump Pressure is Abnor-
mally Low Compared to B
Pump Pressure.
P9BX
B Pump Pressure is Abnor-
mally Low Compared to A
Pump Pressure.
QDAE
Dosing Size A Alarm
*QPDX
Pot Life Timer Expired. Mixed
Fluid Will Cure in Hoses,
Mixer, and Gun.
QTAE
Dosing Size A Advisory
R1BE
Ratio Low B (Under Dose B);
System Delivering Not
Enough B Component.
92
When
Active
Cause
Spray
A air motor is icing causing restric-
tion and lower fluid pressure.
A pump is binding.
A motor is binding.
Spray
B air motor is icing causing restric-
tion and lower fluid pressure.
B pump is binding.
B air motor is binding.
Spray
The fluid dosing size is greater than
45 cc when fast dosing is turned off.
The fluid dosing size is greater than
30 cc when fast dosing is turned on.
Spray
Have not sprayed enough volume to
keep fresh mixed fluid in the integra-
tion hose, mixer, whip hose, and
spray gun.
Spray
The fluid dosing size is greater than
35 cc when fast dosing is turned off.
The fluid dosing size is greater than
20 cc when fast dosing is turned on.
Spray
B dosing valve will not open.
B mix manifold valve closed.
Pump filter plugged on B side.
Solution
Open the air motor de-ice bleed air
controls. Allow ice to melt. Dry com-
pressed air. Heat compressed air.
Use a smaller tip.
Repair lower. See XM PFP repair
manual.
Repair air motor. See XM PFP
repair manual.
Open the air motor de-ice bleed air
controls. Allow ice to melt. Dry com-
pressed air. Heat compressed air.
Use a smaller tip.
Repair lower. See XM PFP repair
manual.
Repair air motor. See XM PFP
repair manual.
Decrease the air motor velocity with
a smaller tip or increase 'B' restric-
tion.
Decrease the air motor velocity with
a smaller tip or increase 'B' restric-
tion.
Spray fluid, or flush. Resets when
you leave spray mode. See Spray,
page 40, or Flush Mixed Material,
page 44.
Decrease the air motor velocity with
a smaller tip or increase 'B' restric-
tion.
Decrease the air motor velocity with
a smaller tip or increase 'B' restric-
tion.
Check for air signal to valve.
Open green mix manifold valve.
Use alternate 30 mesh screen. See
manual 311762 for part number.
Clean B pump outlet filter. See man-
ual 311762.
3A2776H

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xm 262869Xm 262945Xm 262943

Table of Contents