Appendix A - User Interface Display; Change A Setting; Alarms - Graco XM 24W626 Operation Manual

Xm pfp plural-component sprayer
Table of Contents

Advertisement

Appendix A - User Interface Display

Appendix A - User Interface Display
The user interface display is divided into three main
functions: Setup, Command, and Automatic.
Setup Mode Screens (key to right)
Use these screens to:
change between volume and weight ratio
set desired mix ratio by volume or weight
set weight ratio and tolerance for ratio checks
configure system settings
set potlife parameters
enable/disable functions, displays, and display
components
set which USB logs to download
schedule maintenance parameters for alarms
and advisories
set pressure and temperature limits
set tank "fill" and "full" levels
NOTE: Some setup functions must be enabled from the
Enable Setup screens before users can change or set
configurations. See Enable Setup Screens, page 73,
for instructions.
Operator Command Mode Screens (key to left or
removed)
Use these screens to:
run pumps, including flush, circulate, and prime
procedures
park metering pumps so pump rods are down
when not in use
mix and spray
view mix ratio
run pump tests/calibrate weight mode
run batch dispense ratio tests
run valve leak checks
view dispense totals
view alarms
diagnose alarms
clear alarms
set and view A heater, B heater, and hose bun-
dle temperatures
view tank temperatures and levels
Automatically Displayed Screens
These screens are shown when
68
The potlife timer alarms to notify the user that
material is about to cure in the system.
download USB logs.

Change a Setting

All settings are changed in the same manner:
1. Navigate to the desired screen. See Operator
Command Mode Screens on page 76, or Setup
Mode Screens on page 69.
2. Once in the desired screen, use the arrow keys to
navigate to the item that you wish to change.
3. Press enter to enter editing mode.
4. Use the arrow keys to change the selection or
value.
5. Press enter again to save the change or press
to cancel the change.

Alarms

See Appendix B - Alarms, starting on page 86.
3A2776H