Run (Fluid Control) Screens
Run (fluid control) is the first screen displayed at power
on. It enables users to spray material, and operate and
park metering pumps. Run consists of two screens:
power on/enter and ratio mode.
The power on/enter screen cycles through power on
mode, spray mode, pump mode, and park mode. It dis-
plays the current ratio setpoint when in spray mode and
may also display: pressure, temperature and flow rate if
these options are enabled.
The ratio screen displays the current ratio and monitors
the B side restriction adjustment.
Icon
Function
Spray: proportion and spray material.
Icon at bottom of screen: Select which
metering pumps are active. Press repeat-
edly to cycle through metering pump A,
metering pump B, and both metering
pumps.
Icon in rectangle: Operate both metering
pumps.
Operate the A metering pump only (prim-
ing, flushing).
Operate the B metering pump only (prim-
ing, flushing).
Park Metering Pumps: run metering pumps
to bottom of the stroke.
Ratio: jump to ratio screen.
Power On/Enter Mode
Power On/Enter Mode is the default screen when users
enter Fluid Control.
NOTE: This screen remains blank until a mode is
selected.
3A2776H
Appendix A - User Interface Display
Spray Mode
Users must be in this mode to spray or proportion mate-
rial. Press the button below the spray icon to enter this
mode.
Pump Mode
Users must be in this mode to operate metering pumps
for priming or flushing. Press the button below the
metering pump icon to enter this mode. Continue press-
ing the metering pump icon button to cycle through
metering pump A, metering pump B, and both metering
pumps.