Appendix A: I/O Address Function
10. Setup Command
I/O port : 0EE9H
Restart the Setup Command
Enable byte
AA
Using end byte to tell the data flow end
Data
(Delay time)(Startup/Shutdown voltage setting)
11. Onboard CAN Module(Optional Module)
I/O port : 0EEAH
Bit1: Restart or Reset CANBUS Module
0: Don't care
1: RESET CAN Module
Bit2: CAN2_DI Data link detect
0: No data transfer
1: Data link (auto detect)
Bit4: CANBUS Data link detect
0: No data transfer
1: Data link (auto detect)
Copyright © 2012 NEXCOM International Co., Ltd. All rights reserved
Bit5: CAN2_DO Data link detect
0: No data transfer
1: Data link (auto detect)
12. GAL Download control
I/O port: 0EEBH
GAL CODE Download
End byte
55
13. Startup Time Setting
I/O port: 0EECH (Clock timer)
Bit0~7: the hour value (hexadecimal)
I/O port: 0EEDH (Clock timer)
Bit0~7: the minute value (hexadecimal)
I/O port: 0EEEH (User setting time)
Bit0~7: the hour value (hexadecimal)
I/O port: 0EEFH (User setting time)
Bit0~7: the minute value (hexadecimal)
138
Data
Note: Don't initialize this address
End byte
AA