Connecting The Rps Cable And Ac Power Cord; Fastening The Stk-Rps-150Ch8 To The Rack - Enterasys B5G124-24 Hardware Installation Manual

Enterasys b5 series
Hide thumbs Also See for B5G124-24:
Table of Contents

Advertisement

Figure 2-10

Fastening the STK-RPS-150CH8 to the Rack

1 STK-RPS-150CH8 chassis
2 Rails of 19-inch rack
Connecting the RPS Cable and AC
The redundant power supply is connected to a B5 Ethernet switch switch using an RPS cable. 
To connect a redundant power supply, proceed as follows:
1.
Using a Philips screwdriver, remove the cover from the redundant power supply connector 
on the B5 switch. 
2.
Connect one end of the RPS cable to the redundant power supply connector on the B5 switch. 
Then connect the other end of the cable to the redundant power supply connector at the rear 
of the RPS as shown in Figure
3.
Connect the AC power cord to the AC input power connector on the RPS shown in 
Figure
2‐12, then plug the AC power cord into the main AC power outlet. 
The green Power LED on the front of the RPS will illuminate to indicate a successful 
connection. If the LED remains off, proceed as follows:
a.
Check the AC power cord connection at the AC power source and make sure the power 
source is within specification.
b. Check the AC power connection to the RPS.
c.
Swap the AC power cord with a known good one.
d. If the green LED continues to remain off, contact Enterasys
Help" on page xvii for instructions. Otherwise, proceed to step 4.
Installing and Connecting B5 Redundant Power Systems
3 Mounting screws
Power Cord
 
2‐11.
Enterasys B5 Gigabit Ethernet Switch Hardware Installation Guide 2-17