Checking the LEDs
MGR LED
The MGR LED indicates whether the switch is operating as a member or as the manager of the
stack, as described in Table
Table 3-1 MGR LED Definitions
Color
Off
Green
RPS LED
The RPS LED indicates the state of the internal power supply and whether a redundant power
supply is providing power, as described in Table
Table 3-2 RPS LED Definitions
Color
Off
Amber
3-4 Troubleshooting
3‐1.
State
Switch is operating as a member in the
stack.
Solid. Switch is operating as the manager
of the stack.
State
Connected RPS not in use.
Internal power supply failed.
Solid. The switch internal power supply
failed, and the RPS is providing the proper
power to the switch.
Recommended Action
None.
None.
3‐2.
Recommended Action
None.
If an RPS is connected to the switch, it
should be providing power. Perform the
following:
1. Ensure the RPS is powered on.
2. Ensure that the AC power cord to the RPS
is plugged in correctly and that there is
power at the AC power source.
3. Replace the power cord with a known
good one.
4. Ensure the DC power cord from the RPS
to the switch is plugged in correctly.
5. If the problem persists, contact
Enterasys Networks for technical support.