Service Aids; Field Programming - Motorola APX 1000 Basic Service Manual

Apx two-way radios
Hide thumbs Also See for APX 1000:
Table of Contents

Advertisement

4-2
4.2

Service Aids

Refer to
Table 4-2
this family of radios. These kits and/or parts are available from the Radio Products and Solutions
Organization offices listed in
available from Motorola, most are standard shop equipment items, and any equivalent item capable
of the same performance may be substituted for the item listed.
Motorola Part
Number
66012031001
Battery Adapter
NTN4265_
Pressure Pump Kit
NLN9839_
Vacuum Pump Kit
5880384G68
SMA to BNC Adapter
RVN5224_
Customer Programming Software
(CPS) and Tuner Software
PMKN4012B
Programming Cable
PMKN4013C
Programming/Service Cable
RLN4460_
Portable Test Set
PMLN7204A
Chassis/Knob Opener
TL000063A01
Volume Switch Spanner Nut opener
TL000059A01
Vacuum Test Fixture
TL000061A01
Vacuum Cap
TL000062A01
Pressure test fixture
NOTE:
Do not place an order for the Programming Cable (PMKN4012A/PMKN4013B) as it is not compatible
with the APX 2000/ APX 4000 (Two Knobs) radio.
4.3

Field Programming

This family of radios can be aligned and programmed in the field. This requires specific equipment
and special instructions. Refer to the online help in the Customer Programming Software (CPS) for
complete field programming information.
Recommended Test Equipment and Service Aids: Service Aids
for a listing and description of the service aids designed specifically for servicing
"Appendix B Replacement Parts
Table 4-2. Service Aids
Description
Ordering". While all of these items are
Application
Used in place of battery to connect radio to an external
power
supply.
For pressure test.
Vacuum pump with gauge and vacuum hose.
Adapts radio's antenna port to BNC cabling of test
equipment.
CPS allows customer-specific programming of modes
and features. Tuner software required to perform
alignment of radio parameters.
To program the radio through Customer Programming
Software and Tuner Software.
To program and service the radio through Customer
Programming Software and Tuner Software.
For radio performance checks. Connects to radio's
universal connector and allows remote switching and
signal injection/outputs for test equipment measurements.
To remove chassis and knob from housing.
For Volume Switch Spanner Nut.
To connect the vacuum/pressure hose of the
Vacuum Pump Kit to the radio.
To enhance sealing when the vacuum test fixture is
connected to the radio.
To connect the vacuum/pressure hose of the Pressure
Pump Kit to the radio

Advertisement

Table of Contents
loading

This manual is also suitable for:

Apx 2000Apx 4000Apx 4000li

Table of Contents