5-2
Initial equipment control settings should be as indicated in
performance checks and alignment procedures, except as noted.
System Analyzer
Monitor Mode: Standard*
Receiver Checks
RF Control: GEN
Output Level: -47 dBm
Modulation: 1 kHz tone
@3 kHz deviation
Frequency: Set to selected
radio RX frequency
Meter: AC Volts
Transmitter Checks
RF Control: Monitor
Frequency: Set to selected
radio TX frequency
Meter: RF Display
Modulation Type: FM
Attenuation: 20 dB
* Use "PROJ 25 STD" if testing ASTRO Conventional channels.
Table 5-1. Initial Equipment Control Settings
Test Set
Spkr/Load: Speaker
PTT: OFF (center)
Meter Out: RX
Opt Sel: ON
Performance Checks: Test Equipment Setup
Table 5-1
and should be the same for all
Power Supply
Voltage: 7.5 Vdc
DC On/Standby: Standby
Volt Range: 10 Vdc
Current: 2.5 Amps