Alert Forwarding and sending to DVS168/EARS Client
Once forwarding and/or sending have been enabled, four information fields must be configured to identify
the DVS-168/EARS host. See the provided screenshot. Enter the IP address, the IP port, the FTP user and
password, select Audio File Sample Size, and the Audio File Sample Rate (Default is 16000 Sample/sec).
Alerts with all FIPS codes can be forwarded by placing a check mark in the box to enable all FIPS to trigger
DVS168/EARS device. Alerts for specific FIPS areas can also be filtered/passed through the protocol.
Remove the check mark from the box that says All FIPS codes trigger the DVS168/EARS device to enable
FIPS forwarding control. When configured, select a list of FIPS codes that will be used to check against the
incoming forwarded alert. If any of these FIPS are included in the incoming forwarded alert, the alert will be
sent to the DVS-168 client.
Remove the check mark from the box that says All EAS codes trigger the DVS168/EARS device to enable
EAS forwarding control. When configured, select a list of EAS codes that will be used to check against the
incoming forwarded alert. If any of these EAS are included in the incoming forwarded alert, the alert will be
sent to the DVS-168 client.
Setup > Net Alerts > DVS168
 86   
 
   