is used for the external CG hardware.
The USB serial ports offer a few different choices for CG's from compared to the Main serial port.
CG protocols are: Off; Monroe R194 CG; CEMS-0500/1000; Standard TFT; Chyron CODI; VDS; Sage Generic
CG; Sage News Room; XBOB; XBOB4; CG BETABRITE LED Sign; Monroe Envoy; BDI GPM – 300 Matrix
Switcher. The SAGE Newsroom protocol is only available on the USB serial ports. The Monroe Envoy protocol is
NOT available on the USB serial ports. The TFT standard protocol is available, but only one instance of the
protocol will actually be allowed to control audio play-out on the DASDEC II. The first instance configured on
Main or USB ports 1-4 would be granted the privilege of running audio.
Setup > Video/CG > USB Serial 1 web page
As with the Main serial port, a status box is also displayed above the CG radio button selector to inform of the
status of the specific USB serial port. If the port is available (the USB expansion unit is installed) on the DASDEC
II, it would read:
Expansion USB Serial 1 OK