There are three main areas on this page: Automatic Random Required Weekly Test Generation; One-Button and
Automatic Weekly Test configuration; and Front Panel Control.
Automatic Random Required Weekly Test Generation
The checkbox allows you to enable Required Weekly Tests to be automatically generated at a random time
within a pre-selected time frame for specifically selected days. If enabled, controls are displayed that allow
setting the time period and the days for which the test will be scheduled.
Between Start Time and End Time: Enter start time, then end time, in hours and minutes.
On days: Check the days on the Required Weekly Test could be generated. The RWT will not occur on a
day that is unchecked.
Time Configuration Notes:
Configure One-Button and Automatic Weekly Test.
Digital Alert Systems: DASDEC User Manual
When configuring the time period, if first time is greater than the second time, the alert will be
scheduled at a random time from 0 hrs. Midnight to second time or first time to 23:59. If the first
time period is less than the second, the alert will be scheduled at a random time between the first
and the second time entry.
A random Automatic Weekly test is only scheduled if no weekly tests have been originated during
the current week (Sun-Sat).
If changes are made, a previously scheduled weekly test must be manually cancelled before a new
test will be scheduled within the new time frame. See Encoder > Originated Alerts.