Digital Alert Systems DASDEC II User Manual page 64

Digital/analog emergency alert system encoder/decoder
Hide thumbs Also See for DASDEC II:
Table of Contents

Advertisement

requirements.
Serial Port Flow Control – Select Hardware or Software or None depending upon the hardware
support on the remote device.
Throttle down serial port write speed – Defaults to disabled.
When Enabled, data is written with pauses between 128 byte blocks. This can be helpful when sending
this to devices that cannot do flow control.
7.
Chyron CODI CG Attribute Settings
Font - Defaults to one.
Set from 1 to 8.
Color – Defaults to white.
Text over Video Anti-aliased – Defaults to enabled. When enabled, the text is anti-aliases over the
video background.
Iterations – Defaults to one. Crawl is done once.
Set from 1 to 100.
Speed – Defaults to 240 Pix/second.
Choose from a variety of speeds.
Vertical position – Defaults to video scan line 40.
Set from 10 (topmost) to 440 (bottommost).
CODI Serial Port Baud Rate – Defaults to 19200 Select 9600 or 19200 baud depending on the remote
CODI device requirements.
Screen clear – Defaults to enabled. When enabled, the screen is fully cleared of graphics prior to the
EAS text crawl.
Delay crawl – Defaults to disabled. When enabled, the crawl is delayed until after the EAS audio
header and attention two-tone signal is played.
Repeat Alert Video Display – Defaults to Do Not Repeat
Select from a set of options for repeating the data write to the remote device after a pause period set
from the Set Alert Video Repetition Period field. The repeat period has to be at least 2 minutes.
8.
XBOB CG Attribute Settings
Vertical position – Defaults to one.
Sets the vertical location of the crawl on the screen from 0 (topmost) to 16 (bottom)
Solid black background – Defaults to enabled.
When Enabled, the crawl text is set to display on top of a black banner.
Iterations – Defaults to one. Crawl is done once. Set from 1 to 5.
Repeat Alert Video Display – Defaults to Do Not Repeat
Select from a set of options for repeating the data write to the remote device after a pause period set
from the Set Alert Video Repetition Period field. The repeat period has to be at least 2 minutes.
9.
XBOB4 CG
Vertical Line position – Defaults to one.
Sets the vertical location of the crawl on the screen from 0 (topmost) to 16 (bottom)
 58   
 
Digital Alert Systems: DASDEC User Manual
   

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dasdec-1en

Table of Contents