8.12 Cold mirror
How to replace the cold mirror
1. Remove the 2 screws securing the cold mirror bracket to projector base. (image 8-43)
2. Install the new cold mirror (Order No kit: B401040K) unit and reuse the 2 screws to secure on projector base.
3. Proceed to the adjustment of the cold mirror position (see "Light Pad adjustment", page 73).
Image 8-43
Replacement of the cold mirror
R5976766 RLM G5 22/04/2004