Yealink CP860 User Manual page 37

Ip conference phone
Hide thumbs Also See for CP860:
Table of Contents

Advertisement

Enter the starting time and ending time respectively in the desired day field.
2.
Click Confirm to accept the change.
3.
Configuring the Idle Timeout
Idle Timeout specifies the period of time before the IP phone enters power-saving mode. The
following three types of idle timeout you can configure:
Office Hours Idle TimeOut: Configures the idle timeout for office hours.
Off Hours Idle TimeOut: Configures the idle timeout for non-office hours.
User Input Extension Idle TimeOut: Configures idle timeout that applies after you use
the IP phone (for example, press a key on the phone).
By default, the Office Hours Idle Timeout is much longer than the Off Hours Idle TimeOut. If you
use the IP phone, the idle timeout that applies (User Input Extension Idle TimeOut or Office
Hours/Off Hours Idle TimeOut) is the timeout with the highest value. If the phone has an
incoming call or new message, the User Input Extension Idle TimeOut is ignored.
To configure the idle timeout via web user interface:
Click on Settings->Power Saving.
1.
Enter the desired value in the Office Hours Idle TimeOut field.
2.
The default value is 960, you can set to 1-960.
Enter the desired value in the Off Hours Idle TimeOut field.
3.
The default value is 10, you can set to 1-10.
Enter the desired value in the User Input Extension Idle TimeOut field.
4.
Customizing Your Phone
25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents