5.3.4

Status LED

When the 2460 is starting up, all the LEDs are turned on. After 0.5 seconds the yellow (Status) LED is
turned off.
In runtime operation the Status LED (yellow) blinks at a constant rate as shown in
Figure 5-4. Status information is presented by the yellow status LED
Table 5-3. LED sequence in runtime operation
Status LED
(Yellow)
On=50 ms
Off=9000 ms
On=50 ms
Off=200 ms
On=50 ms
Off=8700 ms
On=1000 ms
Off=500 ms
Operation
Description
Full mode
Redundant system; passive
(secondary) Rosemount 2460
Reduced mode (warning)
Operation
March 2017
Table
5-3.
Status LED (Yellow)
87