Network - Emerson Rosemount 2460 Reference Manual

System hub for tank gauging systems
Hide thumbs Also See for Rosemount 2460:
Table of Contents

Advertisement

Service and Troubleshooting
March 2017
6.12

Network

The Network tab lets you configure the Rosemount 2460 for communication on the Ethernet port 1
(Eth1).
Table 6-4. Network configuration
Menu
Mode
IP Address
Netmask
Gateway
MAC address
Specific IP Address for
Primary Device
Specific IP Address for
Backup Device
118
Description
Available mode options are DHCP (dynamic IP address), Static and
Disabled. DHCP is not recommended for redundant systems.
IP address in static mode (common IP Address in a redundant system).
Netmask in static mode.
Enter the gateway's IP address in case the Rosemount 2460 is
connected to the host system via a gateway.
MAC address of the network adapter.
In a system with redundant system hubs, static IP address is
recommended. This field allows you to set a static IP address for the
Primary device in a redundant system.
Can be changed only if the "Redundancy" license option is enabled.
In a system with redundant system hubs, static IP address is
recommended. This field allows you to set a static IP address for the
Backup device in a redundant system.
Can be changed only if the "Redundancy" license option is enabled.
Reference Manual
00809-0100-2460, Rev DB
Service and Troubleshooting

Hide quick links:

Advertisement

Table of Contents
loading