Ac Current Probe Mn193 Probe (With Model 3945) - AEMC PowerPad 3945 User Manual

3-phase power quality analyzer
Hide thumbs Also See for PowerPad 3945:
Table of Contents

Advertisement

3.7 AC Current Probe MN193 Probe
The MN193 is designed to work with secondary current transformers.
Best accuracy is available when entering the transformer ratio (e.g. 1000/5A)
Nominal Range: 5A and 100A
Measurement Range: 5A: 0.005A to 5A
NOTE: Currents below X on the 5A range and Y on the 100A range will be dis-
played as zero on the PowerPad™ with this probe
Probe Output Signal: 5A: 200mV/A
Maximum Clamping Diameter: 0.8" (20mm)
Safety: NF EN 61010-2-032, 600V, CAT III, POLL 2
Reference Conditions:
Ambient temperature
Humidity
Frequency
Distortion factor
Magnetic fi eld of external origin
Accuracy Specifi cations
NOTE: Add PowerPad™ accuracy ±0.5% ± 1ct
Range: 10mV/A (1V @ 100Arms)
Primary current (in A
Accuracy (% of the output signal)
Phase shift (°)
Overload: 120A continuous
Range: 200mV/A (1V @ 5Arms)
Primary current (in A
Accuracy (% of the output signal)
Phase shift (°)
Overload: 12A continuous
Power Quality Analyzer Model 3945
AC
)
AC
)
5mA to 50mA
AC
≤1.5% ±0.1mA
(with Model 3945)
100A: 0.1A to 100A
AC;
100A: 10mV/A
AC;
73°F (23°C) ± 5°F (3°C)
20 to 75% of RH
<1% without superimposed DC current
<40 A/m (earth's magnetic fi eld)
0.1A to 1A
≤1% ±2mA
≤3.2°
0.05A
≤1.5%
≤6.5°
AC
AC
48 to 65Hz
1A to 120A
≤1%
≤2.2°
0.5A
≤1%
≤5°
≤4.5°
5A
≤1%
≤4°
19