Ac Voltage Measurement; Ac Current Measurement - AEMC 601 User Manual

Clamp-on meter
Table of Contents

Advertisement

4.2.2

AC Voltage Measurement

Measurement
range
Specified
measurement
range (2)
Accuracy
Resolution
Input impedance
Note (1)
Above 1000V (RMS), a repetitive beep indicates that the voltage
being measured is greater than the safety voltage for which the
device is guaranteed. The display indicates "OL".
- Bandwidth in AC = 3 kHz
Note (2)
Any value between zero and the min. threshold of the measurement
range (0.15V) is forced to "----" on the display.
Specific Specifications in MAX/MIN mode (from 10Hz to 1kHz, and from
0.30V in AC):
Accuracy: add 1% R to the values of the table above.
Capture of the extreme: approximately 100ms.
4.2.3

AC Current Measurement

Measurement
range
Specified
measurement
range (2)
Accuracy
Resolution
Note (1) - The display indicates "OL" above 2000A.
- Bandwidth in AC = 1 kHz
Note (2)
Any value between zero and the min. threshold of the measurement
range (0.15A) is forced to show "----" on the display.
Residual current at zero <150mA.
0.15 to 99.99V
0 to 100% of the measurement range
0.15V to 9.99V
± (1% R + 10cts)
10.00 to 99.99V
± (1% R +3cts)
0.01V
0.15 to 99.99A
0 to 100% of the measurement range
± (1% R + 10cts)
0.01A
100.0 to 999.9V
± (1% R +3cts)
0.1V
10MΩ
100.0 to 999.9A
± (1% R +3cts)
0.1A
29
1000V RMS
1400V peak (1)
1V
1000 to 2000A (1)
1000 to 1500A
± (1.5% R +3cts)
1500 to 2000A
± (2% R +5cts)
1A

Advertisement

Table of Contents
loading

This manual is also suitable for:

2139.30

Table of Contents