Filter in a grounded line (earthed TN or TT
network)
The filters are suitable for grounded lines only, for
example in public European 400 V lines. Accord-
ing to EN 61800-3 filters are not needed in
insulated industrial lines with own supply trans-
formers. Furthermore they could cause safety
risks in such floating lines (IT networks).

Three - phase filters

EMC filters are necessary to fulfill EN 50081 if a
converter shall be run at a public low voltage line,
in Europe for example with 400 V between the
phases. Such lines have a grounded neutral
conductor. ABB offers suitable three - phase
filters for 400 V and 25 A....600 A and 500 V filters
for 440 V lines outside Europe.
Lines with 500 V to 1000 V are not public. They
are local lines inside factories, and they do not
supply sensitive electronics. Therefore convert-
ers do not need EMC filters if they shall run with
500 V and more.

Single - phase filters for field supply

Many field supply units are single - phase con-
verters for up to 50 A excitation current. They can
be supplied by two of the three input phases of
the armature supply converter. Then a field
supply unit does not need its own filter.
If the phase to neutral voltage shall be taken
(230 V in a 400 V line) then a separate filter is
necessary. ABB offers such filters for 250 V and
6...30 A.
II F 2-22
Converter type
Rated dc current
[A]
DCS600-0025-x1
25
DCS600-0050-x1
50
DCS600-0075-x1
75
DCS600-0100-x1
100
DCS600-0140-x1
140
DCS600-0200-x1
200
DCS600-0250-x1
250
DCS600-0350-x1
350
DCS600-0450-x1
450
DCS600-0520-x1
520
DCS600-0700-x1
700
DCS600-0900-x1
900
DCS600-1200-x1
1200
DCS600-1500-x1
1500
DCS600-2000-x1
2000
DCS600-2500-x1
2500
The filters 25... 2500 A are available for 440 V and 500 V, and the filters
600...2500 A are available for 690 V too.
The filters can be optimized for the real motor currents:
I
= 0.8 • I
; the factor 0.8 respects the current ripple.
Filter
MOT max
Converter type of
dc current
field supply unit
[A]
SDCS-FEX-1
6
SDCS-FEX-2
8
SDCS-FEX-2
16
DCF 503-0050
50
DCF 504-0050
50
further filters for
12
30
The filters can be optimized for the real field currents:
Filter type
Dimensions
L x W x H
xxx = Voltage
[kg]
[mm]
NF3-xxx-25
3
200x150x65
NF3-xxx-50
3.1
200x150x65
NF3-xxx-64
3.1
200x150x65
NF3-xxx-80
9.5
400x170x90
NF3-xxx-110
9.5
400x170x90
NF3-xxx-320
28
450x285x171
NF3-xxx-320
28
450x285x171
NF3-xxx-320
28
450x285x171
NF3-xxx-600
49
590x305x158
NF3-xxx-600
49
590x305x158
NF3-xxx-600
49
590x305x158
NF3-xxx-1000
90
610x305x198
NF3-xxx-1000
90
610x305x198
NF3-xxx-1600 130
840x465x210
NF3-xxx-1600 130
840x465x210
NF3-xxx-2500 200
955x520x293
Filter type
Dimensions
U
= 250 V
max
L x W x H
[kg]
[mm]
NF1-250-8
0.7
139x105x59
NF1-250-8
0.7
139x105x59
NF1-250-20
1.0
139x105x59
NF1-250-55
1.8
230x115x60
NF1-250-55
1.8
230x115x60
NF1-250-12
0.9
139x105x59
NF1-250-30
1.0
148x105x57
I
= I
Filter
Field