Serial Communication Module Function List; Echo Back Enable/Disable Setting For Rs-422/485 Interface - Mitsubishi QJ71C24N User Manual

Melsec-q series
Hide thumbs Also See for QJ71C24N:
Table of Contents

Advertisement

3 SPECIFICATIONS

3.4 Serial Communication Module Function List

Communication with
ASCII code
Communication with
binary code
Read/write of device
memory
Communication using
MC protocol ( 1)
Reading/writing from/to the buffer memory of the Q series C24
Reading/writing from/to the buffer memory of intelligent function modules
Reading/writing from/to sequence program files
Monitoring the programmable controller CPUs (programmable controller CPU
monitoring function)
Status control of the programmable controller CPUs (remote RUN/STOP, etc.)
Turning on/off input signals of the Q series C24 from an external device (global function)
Data transmission from a programmable controller CPU to an external device (on-
demand function)
Data transmission/reception in any format
Data transmission/reception using user frames
Communication using
Data reception by interrupt programs
non procedure protocol
Monitoring the programmable controller CPUs (programmable controller CPU
( 2)
monitoring function)
ASCII data transmission/reception by ASCII-BIN conversion
Data transmission/reception by specifying transparent code
Data transmission/reception in any format
Communication using
Data reception by interrupt programs
bidirectional protocol
ASCII data transmission/reception by ASCII-BIN conversion
( 1)
Data transmission/reception by specifying transparent code
Data transmission/reception by a protocol selected from the pre-defined protocol
Communication using
library
pre-defined protocol
( 2)
Data transmission/reception by a created or edited protocol
Communication via
Communication with MC Protocol/non procedure protocol/bidirectional protocol
public network, etc.
Programmable controller access from GX Developer
(modem function)
DC code control (including Xon/Xoff control)
Transmission control
DTR/DSR control
Independent/linked operation of each interface
Monitoring/testing of initial settings and setting values with utility software
Supporting multiple CPU system
Remote password check

Echo back enable/disable setting for RS-422/485 interface

3 - 14
The following table lists the functions of the Q series C24.
Function
Communication with QnA compatible 3C frame
Communication with QnA compatible 4C frame
Communication with QnA compatible 2C frame
Communication with A compatible 1C frame
Communication with QnA compatible 4C frame Format 5
Batch read/write in bit/word units
Monitoring of device memory
Batch read/write of multiple blocks
Read/write by extension designation
Accessing other stations via network system
1 If the external device is capable of incorporating a program and communicating
data using a protocol of a MELSEC programmable controller, it is possible to
access the programmable controller CPU using the MC protocol.
Communication of any data is also available using the bidirectional protocol.
MELSEC-Q
Reference section
Formats 1 to 4
exist for each.
Chapter 5
Reference Manual
Chapter 6
User's Manual
(Application)
Chapter 7
User's Manual
(Application)
Chapter 8,
Operating Manual
(Pre-defined protocol
support function)
User's Manual
(Application)
Section 4.5.2
Chapter 9
Reference Manual
User's Manual
(Application)
Section 3.3.4
3 - 14

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qj71c24n-r2Qj71c24n-r4Qj71c24Qj71c24-r2

Table of Contents