Functions Available With Utility Package - Mitsubishi QJ71C24N User Manual

Melsec-q series
Hide thumbs Also See for QJ71C24N:
Table of Contents

Advertisement

9 UTILITY PACKAGE (GX Configurator-SC)

9.1 Functions Available with Utility Package

Auto refresh setting
User frame
Data for modem initialization
Data for modem connection
Modem function system setting
CHn Transmission control
and others system setting
CHn MC protocol system
setting
CHn Non procedure
system setting
System
CHn Bidirectional system
setting
setting
CHn Pre-defined protocol
system setting
CHn PLC CPU
monitoring system setting
CHn Transmission user
frame No. designation
system setting
System setting default
System setting write
Flash ROM write allow/prohibit
designation
X/Y monitor/test
Modem function monitor/test
CHn Transmission control
and others monitor/test
CHn MC protocol monitor
CHn Non procedure
monitor/test
CHn Bidirectional monitor
Monitor
CHn Pre-defined protocol
monitor/test
CHn PLC CPU
monitoring monitor
CHn User frame No.
designation monitor for
transmission
Monitor/test others
ERR LED off
Non procedure protocol receive
data clear
9 - 3
The following table lists the utility package function.
(
Function
Refresh the Q series C24's error codes and set devices on
the programmable controller CPU side.
Register the user frame in the flash ROM.
Register the data for modem initialization in the flash ROM.
Register the data for model connection in the flash ROM.
Register the system setting values for model function in the
flash ROM.
Set the transmission specifications with the other device.
(DTR/DSR control, DC code control, communication
method, data communication monitoring timer value, etc.)
Assign the buffer memory for on-demand function, set the
user frame number, etc.
Assign the buffer memory needed to perform data
communication using the non procedure protocol, and
change the setting values, etc.
Assign the buffer memory needed to perform data
communication using the bidirectional protocol, and
change the setting values, etc.
Change the set value for data communication using the
pre-defined protocol.
Set the programmable controller CPU monitoring function.
Set the user frame number to be transmitted, etc.
Reset the setting values in the buffer memory to their
default values.
Write the setting values in the buffer memory to the flash
ROM.
Set whether to allow or prohibit writing to the flash ROM.
Perform the monitoring/testing of I/O signals to/from the
programmable controller CPU.
Monitor the execution status of the modem function.
Monitor the status of interface control signals, values set
from the GX Developer, etc.
Monitor the data communication result, I/O signal status,
and setting values in the buffer memory.
Monitor the setting values and operating status of the
programmable controller CPU monitoring function.
Monitor the setting value for user frame to be transmitted.
Monitor the data reception result, error occurrence status,
etc.
Turn off the ERR LEDs on the front face of the module.
Clear the currently received data.
: indicates that the setting is valid with the applicable protocol.)
MC
procedure
protocol
MELSEC-Q
Non
Pre-
Bidirectional
Explanation
defined
protocol
protocol
Section 4.6
Section 9.4.1
Section 9.4.2
Section 9.4.3
Section 9.4.4
Section 9.4.5
Section 9.4.6
Section 9.4.7
Section 9.4.8
Section 9.4.9
Section 9.4.10
Section 9.4.11
Section 9.4.12
Section 9.4.12
Section 9.4.13
Section 9.6.1
Section 9.6.2
Section 9.6.3
Section 9.6.4
Section 9.6.5
Section 9.6.6
Section 9.6.7
Section 9.6.8
Section 9.6.9
Section 9.6.10
Section 9.6.11
Section 9.7
Remarks
page
Can be
used via
online
operation.
Can be
used via
offline
operation.
Can be
used only
via online
operation.
9 - 3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qj71c24n-r2Qj71c24n-r4Qj71c24Qj71c24-r2

Table of Contents