3 SPECIFICATIONS
Address
Decimal (Hex)
Application
CH1
CH2
For designation
8206
of modem
(200E
)
H
function -3
8456 to
8463
8207
Use prohibited
(2108
H
(200F
)
H
to
210F
)
H
Interrupt
8208
8464
designation
(2010
)
(2110
)
H
H
8209
8465
Use prohibited
(2011
)
(2111
)
H
H
8210
8466
(2012
)
(2112
)
H
H
8211
8467
For transmission
(2013
)
(2113
)
H
H
control
designation
8212
8468
(2014
)
(2114
)
H
H
8213 to
8469 to
8215
8471
(2015
(2115
Use prohibited
H
H
to
to
2017
)
2117
)
H
H
8216
8472
(2018
)
(2118
)
H
H
Communication
8217
8473
data monitoring
(2019
)
(2119
)
H
H
function
8218
8474
(201A
)
(211A
)
H
H
8219
8475
(201B
)
(211B
)
H
H
8220 to
8476 to
8223
8479
Use prohibited
(201C
(211C
H
H
to
to
201F
)
211F
)
H
H
8224 to
8480 to
8227
8483
(2020
(2120
H
H
to
to
For designation
2023
)
2123
)
H
H
of user frame
8228 to
8484 to
receiving method
8231
8487
(2024
(2124
H
H
to
to
2027
)
2127
)
H
H
8232 to
8488 to
8239
8495
(2028
(2128
Use prohibited
H
H
to
to
202F
)
212F
)
H
H
8240 to
8496 to
For designation
8248
8504
(2030
(2130
of transparent
H
H
to
to
code
2038
)
2138
)
H
H
8249 to
8505 to
8255
8511
Use prohibited
(2039
(2139
H
H
to
to
203F
)
213F
)
H
H
3 - 33
Name
Circuit disconnect wait time (programmable controller CPU watch
use)
0000
to FFFF
: Wait time (unit: s)
H
H
System area
Receive interrupt-issued designation
0: Do not issue interrupt.
System area
Transmission control start free area designation
64 to 4,095: transmission control start free area
Transmission control end free area designation
263 to 4096: transmission control end free area
Non procedure and non reception monitoring time format
designation
0: Format-0
System area
Communication data monitoring designation
0000
: No monitor/stopped monitor designation
H
0001
: Monitor start designation
H
0002
: Monitoring (Q series C24 is a set.)
H
1002
: Monitoring stopped (Q series C24 is set.)
H
100F
: Monitor setting error (Q series C24 is a set.)
H
Data optional designation
0: Off
1: On
Full stop designation (b0)
Timer 0 errors at occurrence stop designation (b2)
For system (b1), (b3) to (b15)
Monitor buffer head address designation
(400
to 1AFD
,2600
to 3FFD
)
H
H
H
H
Monitor buffer size designation
(0003
to 1A00
)
H
H
System area
User frame receive format designation (1st to 4th)
0: Format-0,
Exclusive format-1 received data count (1st to 4th)
0 or more: Exclusive format-1 received data count
System area
Transmission transparent code designation (2nd to 4th)
0000
:No designation
H
Other than 0000
:Designated (below)
H
• Transparent code (b0 to b7)
00
to FF
: Transparent code
H
H
• Additional code (b8 to b15)
00
to FF
: Additional code
H
H
System area
1: Issue interrupt.
1: Format-1
1: Format-1
MELSEC-Q
Initial
Protocol
Registration
value
MC Non Bi Pd
0
RW
Allowed
0
RW
Allowed
64
RW
263
Allowed
0
RW
0
0
RW
Allowed
CH1:
2600
H
CH2:
3300
H
(
3)
0D00
H
0
RW
Allowed
0
RW
Allowed
Reference
section
Section 9.4.4
User's Manual
(Application)
User's Manual
(Application)
User's Manual
(Application)
User's Manual
(Application)
User's Manual
(Application)
Section 9.4.7
User's Manual
(Application)
Section 9.4.5
User's Manual
(Application)
3 - 33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qj71c24n-r2Qj71c24n-r4Qj71c24Qj71c24-r2