Syslog Email Configuration - Delta DVS-328 series User Manual

Dvs managed industrial rack mount ethernet switch
Table of Contents

Advertisement

D V S M a n a g e d I n d u s t r i a l R a c k Mo u n t E t h e r n e t S wi t c h U s e r Ma n u a l
Syslog Fwd Table
Fwd Severity
From the drop-down list, select a level of the severity that determines which events are
sent to the syslog server. The log records the messages equal to the configured
severity threshold. For example, if you select an error, the logged messages include
error (3) messages only.
Fwd Address Type
Specify a type of server address and enter the address or the host name in the Server
IP Address field:
 IPv4: The syslog server has an IPv4 address.
 IPv6: The syslog server has an IPv6 address.
 DNS: The syslog server has a DNS host name.
Server IP Address
Enter the IP address or the host name of the syslog server.
Note:
For an IPv6 address, enter the address in the
xxxx:xxxx:xxxx:xxxxx:xxxx:xxxx:xxxx:xxxx format.
Fwd Port
Enter the port number to which syslog messages are sent on the syslog server. Enter a
number between 0 and 65535. Enter 0 to prevent the syslog messages from being
sent.
Fwd TransType
Specify whether log messages are sent as UDP or TCP messages:
 SYSLOG_UDP: Log messages are sent as UDP messages.
 SYSLOG_TCP: Log messages are sent as TCP messages.

3.12.7.4 Syslog Email Configuration

Email Server Configuration allows you to monitor the switch when you can not stay in front of the computer. For
example, when the alarm event happens, you can use a smart phone to get an alarm event email anywhere.
And then you can contact a related maintainer or engineer to check the device and solve the problem.
3 - 11 6
Description
Factory default
None
None
None
514
None