format: First-Sat-May-03:00.
DST EndTime
Enter the daylight saving time (DST) end time. Specify the date and time in the following
format:
Week of the month-day of the week-month-HH:MM.
For example, if DST ends on the second Monday in December at 04:00 AM, enter the
following format: Second-Mon-Dec-04:00.
Note:
1. After you have clicked Apply, the date and time are applied and the fields revert to their default
setting of DD/MM/YYYY and HH:MM:SS.
2. The manual date and time setting will be lost after the switch is rebooted, even if you have
saved the changes

3.1.4.2 SNTP Unicast Server Configuration

If you want to specify a known SNTP server, you can enter the IP address or DNS on this page.

SNTP Unicast Server Configuration

Forward Address Type
Specify a type of SNTP server IP address:
 IPv4: Use an IPv4 address to recognize an SNTP server. This is the default
setting.
 IPv6: Use an IPv6 address to recognize an SNTP server.
 DNS: Use FQDN to recognize an SNTP server.
Unicast Server IP Address
Enter the server IPv4, IPv6 address or host name (FQDN). (Depend on the type you
select in the Forward Address Type field.)
Unicast Server Type
Specify a type of server by selecting Primary or Secondary from the drop-down list.
Last Updated
This field displays the last time the SNTP unicast server updated its time information.
Tx Requests
This field displays the number of SNTP transmit requests made by the switch since it
was last rebooted.
Note:
We recommend that you add the SNTP unicast server for the Delta switch to synchronize the time.
It can make sure that the time on the Delta switch is accurate.
3 - 1 2
Description
Description
Factory default
None
Factory default
IPv4
None
None
None
None