Lldp Interface Configuration - Delta DVS-328 series User Manual

Dvs managed industrial rack mount ethernet switch
Table of Contents

Advertisement

D V S M a n a g e d I n d u s t r i a l R a c k Mo u n t E t h e r n e t S wi t c h U s e r Ma n u a l
LLDP Basic Settings
LLDP Status
Specify the status of LLDP on the switch:
 Enable: LLDP is enabled. You can configure LLDP, and the settings take effect
after you have applied them.
 Disable: LLDP is disabled. You can still configure LLDP, but the settings do not
take effect after you have applied them.
Transmit Interval (8 to 32768)
Enter the interval in seconds to transmit the LLDP frames. Enter a number in the
range of 8 to 32768 seconds.
Holdtime Multiplier
Enter the hold time multiplier in seconds. The hold time multiplier multiplies the
transmit interval to define the Time to Live (TTL) period. Enter a number in the range
of 2 to 10 seconds.
Reinitialization Delay
Enter the delay in seconds before reinitialization. Enter a number in the range of 1 to
10 seconds. A longer time prevents frequent reinitializations.
TX Delay
It is used to delay the tx_relay time and the value is fixed at 2 seconds.
Notification Interval
Enter the interval in seconds for the transmission of notifications. Enter a number in
the range of 5 to 3600 seconds.

3.13.1.2 LLDP Interface Configuration

You can configure the LLDP settings for an individual interface on this page.
Interface Settings
Port
This field displays the interface number.
Link Status
This field displays the status of the interface link.
Admin Status
Specify the status and the direction of the interface:
 TX: The interface processes outgoing traffic only.
 RX: The interface processes incoming traffic only.
3 - 1 2 0
Description
Description
Factory default
Enable
30
4
2
2
5
Factory default
interface number
Up or Down
TX and RX