Loopback-Detection Global Configuration
Module Status
Specify whether the status in global configuration is activated or not.

3.1.9.2 Port Configuration

The parameters of Loopback-Detection should be set for each port.
Notice:
If you need to configure Loopback-Detection Port Configuration, you must enable the
Loopback-Detection Global mode.
Loopback-Detection Port Configuration
Interface
The interface number.
Port Control
Enable/Disable the Loopback-Detection feature on the port.
Recovery Mode
There are two recovery modes for recovering the blocking port. Loops occur as the
reason for blocking the port.
 Auto Mode: After the port is blocked, the port will be automatically linked up after a
recovery interval.
 Manual Mode: After the port is blocked, we have to manually enable the port.
Follow Basic Setting > Port Setting > Port Settings (Admin Mode) to enable the
blocking port.
Recovery Interval
In Auto Mode, the blocking port will be linked up after a recovery interval. The unit is a
second and the range is between 30 and 38400.