Telnet Configuration
Telnet Admin Mode
Specify the status of Telnet.
 Disable: Telnet is disabled.
 Enable: Telnet is enabled.
Telnet Session Timeout (minutes)
The Telnet session timeout period in minutes. When there is no activity and the timeout
period is reached, the Telnet session will be closed. The period must be in the range of
1 to 160 minutes.
Maximum Number of Telnet Sessions
The maximum number of inbound Telnet sessions that are allowed on the switch. The
number must be in the range of 0 to 5.
Current Number of Telnet Sessions
This field displays the number of simultaneous Telnet sessions.

3.1.8.5 Console Port

You can configure the console port configuration on this page.
Console Port
Console Login Timeout (minutes)
The console port session timeout period in minutes. When there is no activity and
the timeout period is reached, the console port session is closed. The period must
be in the range of 0 to 160 minutes. Entering 0 disables the timeout.

3.1.9 Loopback-Detection

A loopback error occurs when the keep-alive packet is looped back to the port that sent the keep-alive
packet.The Delta managed switch provide the Loopback-Detection function to detecting the error in the
network environment.
Notice:
We suggest that the Loopback-Detection function and redundancy protocol should not enable in
the same time because the operating theory of these two functions are conflict.

3.1.9.1 Global Configuration

The module status of Loopback- Detection Global Configuration is used to enable/disable the
Loopback-Detection feature.
Description
Description
C h a p t e r 3 F e a t u r e d F u n c t i o n s
Factory default
Enable
Factory default
30
30
5