Airflow Precautions
Caution -
operating range.
Air flows from the front to the rear of the server.
Follow these guidelines to ensure unrestricted airflow in the server:
Adhere to the minimum airflow clearance specifications. See
■
Specifications" on page
Install the server so the front faces the cool aisle and the rear faces the warm aisle.
■
Do not direct warm air into the server.
■
Prevent recirculation of air within a rack or cabinet.
■
When servicing server internal components, ensure that air ducts and baffles are properly
■
installed.
Route cables so they do not interfere with airflow.
■
Related Information
"Rack Cautions" on page 30
■
"Physical Specifications" on page 17
■
"Electrical Specifications" on page 18
■
"Environmental Requirements" on page 19
■
Proper airflow is essential for keeping the server's internal temperatures within a safe