Electric Installation; Main Unit Connector Configuration - 2N Helios IP Base Installation Manual

Door entry ip intercom
Hide thumbs Also See for Helios IP Base:
Table of Contents

Advertisement

2.3 Electric Installation

This subsection describes how to connect the
power supply and LAN and how to connect other elements. Connection of RFID
reader modules is contained in section

Main Unit Connector Configuration

Description board connectors accessible to users:
Legend
LAN (PoE)
X12 Connector
Tamper
IN
OUT
RELAY
12V
2N TELEKOMUNIKACE a.s., www.2n.cz
2.4 Extending Module Connection
LAN (PoE according to 802.3af) connector
The connector for RFID Reader modules
Output of internal security intercom contact
Terminals for input in passive / active mode (-30 V to +30 V DC)
OFF = open OR UIN > 1.5 V
ON = closed contact OR UIN < 1.5 V
OUT1 active output: 8 up to 12 V DC depending on power supply (PoE: 10
V; adaptor: power supply voltage minus 2 V), max 400 mA
Terminal 30 V / 1 A AC/DC NO/NC contact
External 12 V / 2 A DC power supply terminals
®
2N
Helios IP Base
main unit to the
.
27/60

Advertisement

Table of Contents
loading

Table of Contents