4 Operation of the Application
4.3 Monitoring and parameter access via operator panel
When (de-)activating the manual mode, the control word and the setpoint
value are not adjusted. It is therefore possible when switching over that
SINAMICS G automatically starts up or changes the speed.
DANGER
In this example, this enables switching from the digital inputs to manual operation
via HMI. The set control word bits are then displayed yellow.
Setpoint and actual values
Figure 4-3
Setpoint speed value:
Here, the setpoint speed value is displayed which in this example, is set via the
digital inputs E0.4 to E0.7 (see
In manual mode, the speed setpoint value is directly specified via HMI, the input
field is then shaded yellow.
When (de-)activating the manual mode, the control word and the setpoint
value are not adjusted. It is therefore possible when switching over that
SINAMICS G automatically starts up or changes the speed.
DANGER
Actual values:
The current actual values for speed, electrical current and torque are displayed
below the speed setpoint value input.
SINAMICS G120C at S7-300/400F-DP
Beitrags-ID: 60441457,
V2.2,
Table
11/2014
4-1).
34