2.2 Connection of AC Power Cable

After connecting the signal cable, insert the AC power cable's plug into the Library's AC power
connector. Make sure that the plug is fully inserted.
When the redundant power supply is installed in the library, insert the AC power cable's plug into
each Library's AC connector.

2.3 Power-On and self test

Turning on the power of the unit starts power-on sequence automatically.
For description of power-on, see "3.1Power-On and Power-On Sequence".

2.4 Setting Drive configuration

Set the interface configuration in the drive module referring the panel operation in
Configuration
4.4.2
.
[SAS interface]
・Drive Path
・Media Changer Path
・Link Speed
・Power Save Mode
[FC interface]
・Control Path
・Media Changer Path
・Topology
・Loop ID
・Link Speed
・Power Save Mode
When a wrong topology, Loop ID, and Link Speed are set, the entire system might be
negatively affected.
・Please set it to the loop when connecting directly with HBA.
・Please set it to Point to Point when you pass the FC switch.

2.5 Setting Library and Drive configuration

After the library starts normally, the composition of the library and the drive can be set.
1.Setting of library and drive
(1) Setting of Fibre Channel or SAS
(2) Setting of drive port / media changer path
(3) Setting of I/O Station
(4) Setting of slots
2.Setting of Network
(1) Setting of IP address
(2) Setting of subnetmask
(3) Setting of gateway
(4) Setting of DHCP
3.Setting of Time
Since time information is reset (2000/1/1/00:00:00) when the state of the equipment power supply
OFF continues, please carry out a time setup again after the power supply ON.
The setting of drive path
The setting of the media changer path of the robot
3Gbps、6Gbps
The setting of drive power save mode
The setting of drive path
The setting of the media changer path of the robot
Point to Point / loop
0 to 125
Auto、1Gbps、2Gbps、4Gbps、8Gbps
The setting of drive power save mode

Table 2-1 Setting item

Setting item
-29-
procedure
4.5.3.1 or 4.5.3.2
4.5.3.3
4.5.5
4.5.6
5.2
5.2
5.2
5.2
4.4.2.5 or 5.6.5.5