Loading System Software using DHCP

5.2.2 Connect a Console Maintenance Terminal to the Switch

The HN4000e and HN4000i switch models use different types of connectors for their maintenance
terminal interfaces. HN4000e switch models use an RJ-45 connector;
Note
HN4000i switch models use a DB-9 connector.
Step 1. Connect the maintenance terminal's serial cable to the HN4000 switch's RJ‐45 Console 
port (HN4000e switch model) or DB‐9 Craft port (HN4000i switch model).
Figure 5-3
Connecting Craft Port Cable (HN4000i Switch Model Shown)
Step  2. Configure the communication settings of the maintenance terminal (or a personal 
computer's terminal emulation program) to:
Step  3. Start a communication program on the maintenance terminal. For example, a pro‐
gram such as HyperTerminal (on a computer using Microsoft Windows).
When the maintenance terminal is connected to the craft port, the Login prompt of 
the CLI should appear. If it does not, press the maintenance terminal's <Enter> key 
several times. 

5.2.3 Use the CLI to Enable DHCP on the Management Port

Step 1. Log into the CLI using the default administrator username and password, or the 
administrator username and password you have been provided.
Press the <Enter> key after typing your username and password.
HN4000 Hardware Installation Guide
9600 baud
No parity
8 data bits
1 stop bit
Hardware flow control set to Off
CLI passwords are case sensitive and password characters are not echoed to the
Note
terminal.
920550-5020 Rev 14