Lamp Test Button; Testing The Device's Lamps - Hatteras HN4000 Hardware Installation Manual

Table of Contents

Advertisement

3-4

Lamp Test Button

3.3
Lamp Test Button
The LAMP TEST button (Figure
the button is pressed. Starting with release 5.0.0 of the system software, the HN4000's lamp test 
button can be set (using the config system command's lampTestButton argument) to operate 
in one of the following ways:
1. the basic lamp test and alarm cutoff operations (press the button for less than two seconds 
to test the lamps and press the button for more than two seconds to reset the alarm port's 
relay contacts).
2. a switch reboot operation in addition to the basic operations (press the button for more 
than 10 seconds to reboot).
3. a switch renumbering operation in addition to the basic and reboot operations (press the 
button for more than five seconds, but less than 10 seconds). The switch‐number LED will 
blink. Press the button to select a new switch number (which must be unique within the 
stack). After you make the selection, the switch will reboot.
The default setting is to support all four operations as described in #3 above (lamp test, alarm cut-
Note
off, reboot, and renumbering).
Figure 3-4
Lamp Test Button
In releases of the system software prior to release 5.0.0, all three lamp test operations are
Note
enabled.

3.3.1 Testing the Device's Lamps

If you press and hold the LAMP TEST button for less than two seconds, all of the device's 
LEDs will illuminate while the button is pressed.
If you press and hold the button for more than two seconds but less than five seconds, the 
LEDs return to normal operation.
HN4000 Hardware Installation Guide
3‐4) provides multiple functions, based on how long
920550-5020 Rev 14