6. Commissioning
State 5t
Burner for central heating operation 30 Temperature control
3
DHW mode running
4
Burner stop
5
Boiler stop (End of heat demand)
6
Control stop
8
Blocking
9
17 Bleed
6.7
Changing the settings
68
CALORA TOWER GAS 15S EX CALORA TOWER GAS 25S EX
Sub-status 5v
31 Limited temperature control (ΔT safety)
32 Output control
33 Temperature protection gradient level 1 (Modulate down)
34 Temperature protection gradient level 2 (Part load)
35 Temperature protection gradient level 3 (Blockage)
36 Modulate up for flame control
37 Temperature stabilisation time
38 Cold start
30 Temperature control
31 Limited temperature control (ΔT safety)
32 Output control
33 Temperature protection gradient level 1 (Modulate down)
34 Temperature protection gradient level 2 (Part load)
35 Temperature protection gradient level 3 (Blockage)
36 Modulate up for flame control
37 Temperature stabilisation time
38 Cold start
40 Burner off
41 Post ventilation
42 Close flue gas damper/external gas valve
43 Recirculation protection
44 Stop fan
60 Pump post circulation
61 Pump off
62 Control three-way valve
63 Start anti-hunting
0 Wait for burner start
1 Anti-hunting
xx Shutdown code xx
0 Rest
2 Control three-way valve (Heating)
3 Start pump
61 Pump off
62 Control three-way valve (DHW)
The boiler control panel is set for the most common heating
systems. With these settings, practically all heating systems operate
correctly. The user or installer can optimise the parameters according
to own preferences.
6.7.1.
Parameter descriptions
CALORA TOWER GAS 35S EX
22/04/2016 - 300026141-001-07