5. Installation
5.5

Hydraulic connections

28
CALORA TOWER GAS 15S EX CALORA TOWER GAS 25S EX
4. Put the 2 screws in place at the front to attach the boiler to the
DHW tank.
5.4.3.
Positioning the boiler to the left or right of
a DHW tank
1. Put the DHW tank in place.
¼ Refer to the DHW tank's installation, use and maintenance
instructions.
2. Position the boiler beside the DHW tank.
¼ See chapter "Positioning the boiler on its own", page 25
5.5.1.

Flushing the system

n Fitting the appliance to new installations
4 Clean the installation with a universal cleaner to eliminate debris
from the system (copper, hemp, flux).
4 Thoroughly flush the installation until the water runs clear and
shows no impurities.
n Fitting the appliance to existing installations
4 Remove sludge from the installation.
4 Flush the installation.
4 Clean the installation with a universal cleaner to eliminate debris
from the system (copper, hemp, flux).
4 Thoroughly flush the installation until the water runs clear and
shows no impurities.
CALORA TOWER GAS 35S EX