5.11 Filling the system
22/04/2016 - 300026141-001-07
PCU
Primary control unit
SONDE DHW Domestic hot water sensor X121 Reversal valve
SONDE EXT
Outside sensor
X111
SU bus connector
Water pressure gauge
X114
Return temperature
X115
Flow temperature
5.11.1.
In most cases, the boiler and the central heating installation can be
filled with normal tap water and no water treatment will be necessary.
5.11.2.
1. Open the cold water inlet and heating outlet valves.
2. Open the filling/draw-off valve on the heating system.
T000181-B
3. Close the filling valve when the pressure gauge shows a pressure
of 2 bar.
X117 Limiter thermostat, top
X21
Gas valve
X22
Ignition transformer
X41
BO PUMP 230V
X91
Fan
ZG
General switch
Water treatment
WARNING
Do not add chemical products to the central heating water
without consulting Remeha. For example: antifreeze,
water softeners, products to increase or reduce the pH
value, chemical additives and/or inhibitors. These may
cause faults in the boiler and damage the heat exchanger.
For untreated water, the pH value of the water in the
4
installation must be between 7 and 9 and for treated
water between 7 and 8,5.
The maximum hardness of the water in the installation
4
must be between 0,5 - 20,0 °dH (Depending on the
total installed heat output).
For more information, refer to our publication water
4
quality rules. The rules in the aforementioned
document must be respected.
Filling the system
CAUTION
Before filling, open the valves on every radiator in the
installation.
In order to be able to read off the water pressure from the
boiler display, the boiler must be switched on.
5. Installation
53