7.7

Analog Output Setup

The flowmeter provides current, voltage and pulse-rate analog outputs. The [Analog Out Setup]
menu allows you to assign data functions for these signals. The transmitter terminal strip
contains the analog output terminals.
Table 7-6
Io (Isolated Current)
Vo (DC Voltage
Pgen (TTl Logic)
Table 7-7
Vfo
Vfab
Vs
Valc
Vaer
T1
Io Output Functions
Assigning a function to the current output:
1. From the [Dual Path Flow] menu scroll to [I/O Data Control].
2. Press <Right Arrow] to highlight the [Analog Out Setup] menu.
3. Press <Right Arrow> twice to access the [Io1] option list.
FUP1010 IP67 Portable Flowmeter
Operating Instructions, 02/2010, A5E02951522A Revision 01
Analog Outputs
Analog Out Setup Data Categories
7.7 Analog Output Setup
4 to 20 mA varies in proportion to an assigned data
function.
0 to 10 Vdc varies in proportion to an assigned
data function.
0 to 5000 Hz varies in proportion to an assigned
data function.
Spanned volumetric/mass flow.
Spanned unsigned flow magnitude.
Spanned liquid sonic velocity.
Receive signal amplitude.
Relative degree of liquid aeration/cavitaion.
Current liquid temperature.
Functions